  1. D

    SWG Cell comparison

    Post Mortem, lessons learned... JasonLion, you were correct, the low salt level caused the new cell to have problems as well, which is why the check cell light remained illuminated. No need for me to contact the manufacturer. Once I raised the salinity, and reset the SWG, the new cell is...
  2. D

    SWG Cell comparison

    Yes, confirmed that the cell type (t-15) is correct on the diagnostic display. Salt level is very low, but I thought that was due to the bad cell (it dropped rather drastically just before the check cell light came on). I could add a few bags of salt...but as you say, it seems unlikely that...
  3. D

    SWG Cell comparison

    Water temp is +/- 70 degrees. Connections seem solid. After startup, the Power and Generating lights are lit...but after a few minutes of it running, the Generating light goes off, and the Check salt and Check cell lights come on (solid).
  4. D

    SWG Cell comparison

    I just installed a new Hayward T-15 cell, restarted the system, and my Aqua Rite control panel still has a solid light for the Check Cell. Now what???
  5. D

    SWG Cell comparison

    Since my entire system is more than 3 years old, I would think it is no longer under warranty. So I will need to weigh the risk factor of the CompuPool cell (with a warranty that comes with that) against the possible inconvenience of it not working well. Thank you for your insight and prompt...
  6. D

    SWG Cell comparison

    Perfect...that answers that. What are your thoughts (if any) on the off brand CompuPool T-15 cell instead of the name brand one from Hayward?
  7. D

    SWG Cell comparison

    I have a Goldline T-Cell-15 that I am going to have to replace. I was considering going with a T-Cell-9, since by my calculations, my pool/spa is below 25,000 gallons, and thought I would save some money. Is this shortsighted thinking? Am I better off paying a little more now and staying with...