Recent content by Darkmanh

  1. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @ajw22 I installed the new board and 6 button pad and it worked like a charm🥳 Thank you so much for your help.
  2. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @ajw22 I’ve checked again that all connections are correct and that the voltages are correct. Also, I’ve received the updated board and 6 button membrane with FC connector. I will be installing them today and post the results. Thank you!
  3. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @ajw22 this morning I reinstalled the original board and new fuse. I followed the step by step process of plugging in each J connector and checking the fuse. I was able to plug in all the connectors and the fuse is still good. I check voltages to the FS and they’re 24VAC but the display on the...
  4. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @ajw22 the troubleshooting guide from the manual is what I followed. So you mentioned a 24v safety sensor which I had no idea about. How does that work? I ordered more fuses because I depleted the 10 I had so I’m planning on testing the original board again. I will return the board I ordered...
  5. 1670106805749.png

    1670106805749.png

  6. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    At this point I don’t know if the old board is bad. The last test I did with the original board I was able to connect all the connectors and membrane pad and the fuse didn’t blow. However, the heater was not displaying anything and none of the LEDs worked. I tried removing the membrane pad and...
  7. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @ajw22 the fuse doesn’t blow with just J7 connected to my original board but there's nothing on the display and the heater doesn’t start. When I plug in the new board just to J7 the fuse blows.
  8. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    Here’s my fireman switch removed for inspection
  9. image.jpg

    image.jpg

  10. image.jpg

    image.jpg

  11. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    This is my original board
  12. image.jpg

    image.jpg

  13. Darkmanh

    Pentair Mastertemp 250 24 VAC short keeps blowing fuse

    @awj22 I checked the fireman switch and it’s in perfect condition. I also checked the wires to the FS and they do not have conductivity to ground so I guess the issue is with the control board? I actually ordered 2 control boards from amazon. They are the same model as the original one but look...