Recent content by ColoradoKid

  1. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    On a side note, we just bought and installed a RayPak Avia 400 to replace our Pentair unit. I have to say the Raypak is leagues better as far as build quality goes.
  2. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Hey, sorry, I just sent it back to the supplier on eBay (and got a full refund so that's good!)
  3. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Hi All, update- The “new” generic board was indeed bad. Plugged in the new Pentair circuit board and everything works perfect now. So lesson here is don’t buy generic circuit boards off eBay! Thanks for everyone’s help.
  4. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    I'm ordering new "authentic" board. Hope that's it. Allen, you mentioned, ", you will also need to update the heater to have the 6 button keypad." Do you just mean to get the associated membrane or is there any additional wiring needed? Thanks.
  5. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Also, huge thanks for everyone's input. Much appreciated.
  6. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Was sold out so link didn't work, but here's a screen shot: They claimed it worked with all MasterTemps. Obviously didn't for mine.
  7. Screen Shot 2023-03-19 at 8.56.53 PM.png

    Screen Shot 2023-03-19 at 8.56.53 PM.png

  8. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    So my fear is if I buy a new (and correct) board, will it just cook it?
  9. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Oh wow, good eyes. yes looks like my "new" board is different. I got it off Ebay with the membrane pad.
  10. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    It's currently wired now that is the same of how it was for the 4 years since our pool install. Didn't change any wiring around. Now that the new board is cooked, I'm thinking back at what was the original and first issue that I noticed. And that is the heater seemed to disconnect from the...
  11. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Also just noticed this (on the new board I just installed)
  12. D298B72E-CCB5-4EEF-A3EA-1A36D7ECA2ED.jpeg

    D298B72E-CCB5-4EEF-A3EA-1A36D7ECA2ED.jpeg

  13. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    Here it is now. (Notice I wired back the yellow wires as was before (not jumping the fireman switch)
  14. D21D1E62-A1CF-40A0-A809-26B53269169D.jpeg

    D21D1E62-A1CF-40A0-A809-26B53269169D.jpeg

  15. C

    HELP - Pentair Mastertemp 250 Not connected to EasyTouch and now won't start

    The Display doesn't show anything. The membrane also appears dead. Pool/Spa buttons do nothing. Up/down, nothing. No lights whatsoever. I don't have a pic right now, but this is what I mean by the "yellow" wires. I saw on another thread to wire like this to get it started. Nothing...