Recent content by ClubJuan

  1. C

    OmniLogic not detecting HUA for Hayward VSP

    Just spoke with the Hayward rep. He said that I need a new Digital Display, Part#VSX3400LCD, for the 3400VSP since my unit is so old(18 months) and predates OmniLogic. Got it ordered and should have it to install by the weekend. Only $328.76 on Amazon(sarcasm). Will post update.
  2. C

    OmniLogic not detecting HUA for Hayward VSP

    I have the Ecostar pump, Hayward SP3400VSP, which I upgraded to in 11/2013. Before the Omnilogic install I had the ProLogic panel that only allowed setup as a 2 speed pump. The old panel had issues like failing to turn on my chlorinator from time to time, overheating and one time it didn't reset...
  3. C

    OmniLogic not detecting HUA for Hayward VSP

    I just installed the new Omnilogic Control Panel. When I try to configure the VSP, it does not show up in the list of detected devices. It appears that the OmniLogic panel is unable to "see" it and therefore unable to obtain it's HUA. High voltage wiring is directly to the breaker. Low voltage...
  4. C

    Omnilogic not talking to ecostar/Firmware Issue?

    "3. My concern in the initial post about Ecostar firmware was not an empty one. Apparently some older Ecostar firmware does not publish its unique address which is required for integration with Omnilogic. To update firmware a digital interface control part (a top part with buttons and...