Recent content by cj7ngolf

  1. C

    Low Apm on Digi 220 Pool Pilot SOLVED

    Re: Low Apm on Digi 220 Pool Pilot well, after troubleshooting, and reading some more on here and in other places on the interweb, I decided, since I have some electronics knowledge, to replace the capacitors on the power board. Ran around locally and found... Nothin... looked through some...
  2. C

    Low Apm on Digi 220 Pool Pilot SOLVED

    Re: Low Apm on Digi 220 Pool Pilot Sorry, forgot to mention, unit was in boost mode for at least 30 min for each of the above readings. I looked at cable ends, and they are clean, ohm'd out cable and it checks good, pulled cover off unit and noticed caps in upper left appear to be swollen and...
  3. C

    Low Apm on Digi 220 Pool Pilot SOLVED

    Re: Low Amp on Digi 220 Pool Pilot Went and checked on power level 1 and was at 13v 2.4 amp
  4. C

    Low Apm on Digi 220 Pool Pilot SOLVED

    I have an 17,500 gal AG pool with a digi220 and an sc36 cell. currently set up on 110VAC Getting Low amp light/reading. replaced cell with compupool cell and same thing. on boost for 30 min, got 2700 ppm salt, power level 2 15v 3.7 amp put on power level 1 and am getting ready to go...