Recent content by chuckcohio

  1. chuckcohio

    Another IF code problem

    Sorry, I didn't even think about getting an amp draw. I'm going to look at this some more as time allows. Maybe try to upload a video. Thanks again, Chuck
  2. chuckcohio

    Another IF code problem

    After checking everything I could possibly check, rotated The gas line checked the orifices they were clear. I did get a separate 24v transformer and powered the gas valve. It clicked but had no flow. I powered it probably a half dozen more times and it finally actuated. I tried it several more...
  3. chuckcohio

    Another IF code problem

    Okay, that sounds very reasonable, I'll grab another 24v transformer and give that a try I think I've got one laying around somewhere. I appreciate the help and I'll keep everyone informed. Thanks, Chuck
  4. 16835787460362965144953449933582.jpg

    16835787460362965144953449933582.jpg

  5. 16835786278676107756127862235169.jpg

    16835786278676107756127862235169.jpg

  6. chuckcohio

    Another IF code problem

    It's 3 years old, I'll have to send the exact information when I get home, about 2 hours from now
  7. chuckcohio

    Another IF code problem

    I did try it remove the wire from the gas valve thinking it was possible overload condition, the voltage did just drop off the same as it did when attached. Thanks for the reply, Chuck
  8. chuckcohio

    Another IF code problem

    Hi, thanks for your response. No woosh, the gas valve doesn't even get power for more than a split second. Then The Purge process starts over gas valve just gets power for a split second and, everything starts over Thanks, Chuck
  9. chuckcohio

    Another IF code problem

    Hayward swimpro h series 150000 btu heater. I'm an electrician by trade and really have no experience with this kind of thing but, here's what I've done and I'm hoping someone here has an answer. Everything seems to be going good on the startup sequence but as soon as the purge is done and The...