Recent content by chicoDaMan

  1. C

    Excessive water restriction in gas heater?

    Yes. As you pointed out, 1" pipe is pretty small. Standing down in the pump pit and taking a close look, you could see that it was smaller than the rest of the system plumbing. Don't know why it was originally installed that way. Downloaded the installation manual, 1.5" CPVC is what is spec'd...
  2. C

    Excessive water restriction in gas heater?

    That makes sense. In fact, I'm thinking of using a motorized Jandy valve as an external bypass valve and connect it to the heater logic to bypass the heater externally when the proper heat is reached. Why keep pushing water through a restricted passageway when the heater's not running? It...
  3. C

    Excessive water restriction in gas heater?

    With the gas heater, the pump runs 2273 RPM @ 17 psi (525 watts). Bypassing the gas heater, the pump drops to 1345 RPM @ 5 psi (145 watts). OK, thanks. Seems like a lot of wasted power, nearly 400 extra watts to push water through the heat exchanger. As an engineer, that makes me roll my...
  4. IMG_8529.JPG

    IMG_8529.JPG

  5. C

    Excessive water restriction in gas heater?

    (sorry, I was probably resizing the photos when you first accessed my post)
  6. IMG_8525.JPG

    IMG_8525.JPG

  7. IMG_8513.JPG

    IMG_8513.JPG

  8. IMG_8515.JPG

    IMG_8515.JPG

  9. C

    Excessive water restriction in gas heater?

    Hi - "Just the facts, ma'am..." ;) My brother has a 10,000 gallon uncovered shaded pool at his personal and rental home in Mexico with a Pentair Intelliflo VSF pump, Hayward Pro Series 3.1 sq.ft. sand filter and a 480 sq.ft. roof-mounted solar hot water array three stories above the pool. The...
  10. C

    How to wire solar valve to Pentair EasyTouch panel?

    Great story! Yikes. Not the best QC on stuff intended to keep the a human being alive. Worst case scenario pretty grim. OTOH, the QC on the Pentair board appears pretty bad too. But worst case for Pentair is they get to overcharge for another board (unless the user is geeky enough to fix it...
  11. IMG_8146.JPG

    IMG_8146.JPG

  12. C

    How to wire solar valve to Pentair EasyTouch panel?

    Found it. I traced out the circuit board, all looked ok. Definitely appeared to be a bad relay. But I was hesitant to unsolder and replace the relay in fear of lifting or damaging the traces, some of which run under the relay bodies. That could get ugly. I noticed a lot of crusted solder flux...
  13. C

    How to wire solar valve to Pentair EasyTouch panel?

    Just went out and checked. The three other valve drivers (intake, return and B Valve) indeed have 29VAC (no load) across left and middle pins. So the AC source transformer appears to be ok. But there's high impedance on all the pins of A valve...I get varying AC values that change significantly...
  14. C

    How to wire solar valve to Pentair EasyTouch panel?

    Yeah, I've blown a few expensive boards before. Good way to feel really stupid! But I've got a 3-pin connector with loose wires that I can use to protect against stupidity a little bit while measuring...:rolleyes: Yeah, that's exactly how I expected it would work. When it didn't I figured I...
  15. C

    How to wire solar valve to Pentair EasyTouch panel?

    Good idea. I assume from your suggestion I should be able to measure 24VAC between two of the pins on the connector. Do they all have similar pinouts?