Recent content by cgonzal2

  1. C

    Mini Max pool heater

    Yes, most of the wires melted. But it just so happened that a different sister was replacing her Spa Heater. And the old one was just like the one that my other sister neede. Man, this can get complicated. I did re-wire the entire system at first until we found out that the wiring harness from...
  2. C

    Mini Max pool heater

    This unit used to work until the heat in the cabinet burned up all the wiring. The circuit board had a burned trace as well, so I decided to just replace it. The electronic ignition was also damaged. So, I've replaced all of the major electrical parts, which were all damaged. New circuit board...
  3. C

    Mini Max pool heater

    My sister had some issues with her pool heater. It turns out that the circuit board and all the wiring burned up. I replaced the circuit board, wiring, and gas valve. Once turned on, the "HEAT" LED on the circuit board fails to come on. The Service Light LED is lit. Any suggestions? I posted a...
  4. C

    Pentair MiniMax pool heater

    Update: I found an open trace in the pcb. It looks like the thermal switch failed to open due to the heat in the chamber. The trace on the pcb burned. I replaced it with a wire. And plan on replacing the Thermal Fuse. I'll post tomorrow. cat
  5. C

    Pentair MiniMax pool heater

    Hello to all, a newbie here, found this forum online and decided to try it out. My sister has a pool with a Pentair 400 heater. She had some problems with the control system. Got it all buttoned up and turned it on yesterday. The thermostat control card has 6 indicator led's. The service led is...