Recent content by bscatron

  1. B

    Pentair IC40 all green lights but not producing chlorine

    Well, I have a strange situation. A licensed Pentair partner had me run the cell disconnected from the pump. I first filled it with water (cap on one end) and pressed the flow switch with my finger. I watched it bubble and quickly produce a lot of chlorine. I also tested it while attached...
  2. B

    Pentair IC40 all green lights but not producing chlorine

    Hi Jim, thanks for commenting. I using Clorox OTO drops. My pool is crystal clear, and I did a quick acid cleanse of my chlorinated just in case. The green light stays on all the time (I believe) because I have it set to 100%. I even tried “boost,” and the green light does its 1,2,3,4,5...
  3. B

    Pentair IC40 all green lights but not producing chlorine

    I’ve run my intellichlor for 48 hours on high (even boost for 24) and tested the water directly out of the jet. Chemistry effects chlorine retention, but does it effect production?