Recent content by BrownDogs

  1. B

    Is my equipment suitable to convert to Salt Water Pool with SWG?

    That's great news. Thanks for the help. Now I must decide which SWG is best for me. I don't have any automation yet. Not too much to control (pump, heater, pool light, some backyard lights and now the SWG) so I will have to think and research more about SWGs and automation systems. I don't...
  2. B

    Is my equipment suitable to convert to Salt Water Pool with SWG?

    I have a newly re-plastered (with quartz) in-ground pool. I want to convert it to a salt water pool with a SWG. I have a old fiberglass filter. It is a Titan Vertical Grid Filter, DE, 48 sq ft, Model 56623100 from American Products. It says "Suitable for fresh water pool only" so I am concerned...
  3. 1743048108904.png

    1743048108904.png

  4. 1743048488692.png

    1743048488692.png

  5. B

    Pool Return Aerator Help

    Thanks! Reading it now. :)
  6. B

    Pool Return Aerator Help

    Thanks for the quick replies PoolStored and ajw22. :) I just tested now the newly filled pool. I tested with my test kit (see sig). FC 0.5 CC 0 pH 7.2 TA 140 CH 275 CA 5 After filling with new water the pH was 8.1. TA was at 165. Over the last 3 days, I have been adding Muriatic Acid 30 oz at...
  7. B

    Pool Return Aerator Help

    I have a newly re-plumbed and plastered pool. In my old (circa 1958) in-ground pool, I had only 1 copper return. The builder just now put in all new PVC including new skimmer, main drains, vacuum port and 3 returns. I need to raise pH so I need to aerate. I'd like to know how these return jets...
  8. 1742841521339.png

    1742841521339.png

  9. B

    How much DE to add to a clean filter?

    Thanks guys. I appreciate the link to the filter manual, ajw22. I know that most of the info I have read says 1 lb. per sq. ft. and so did the old bag of DE. The new DE (box of Dicalite) says that for 50 sq. ft. to use 7.5 lbs. to precoat. I used 6.25 lbs. this time fo my 48 sq. ft. filter. But...
  10. B

    How much DE to add to a clean filter?

    How much DE to add to a clean filter? I have just removed and deep cleaned my DE filter. I’m wondering how much DE to add? And if I added enough? It is a 48 sq. ft. Titan Vertical Grid Filter. When I did it the last time, I felt it was not full of enough DE. I put what I thought was 5 lbs. but...
  11. PXL_20230408_193333289.jpg

    PXL_20230408_193333289.jpg

  12. B

    High CYA and Black Algae

    Does a 200 ppm CYA level invite Black Algae? Seems like I can't keep a high enough chlorine level with this high of a CYA. Black Algae is mostly on the walls with some now spreading down the deep-end walls and a just little on the bottom. To find the 200 ppm CYA value, I used the Pentair Rainbow...
  13. B

    Hello to Everyone

    I'm a new owner of an old pool. Just learning how to take care of it myself. Steep learning curve but I'll push thru and figure it out. The pool is nothing fancy but that's fine for us. I've attached a photo of it and filled out my signature and profile if you want to get more details. I found...