Recent content by Binkstwo

  1. B

    Return water pressure too low

    OMG!!! Who knew a 1.00 gasket could cause such a problem. the pool center that we bought the motor from put it together for us---motor, impeller, diffuser. after we read your reply, we took the motor out and saw that there was no gasket on the diffuser! We put one on ,reattached the motor and...
  2. B

    Return water pressure too low

    We have large cartridge filters. we took the filter out with no change in water pressure. there are no pressure gauges on the equipment that we have so I can only tell that the water flow back into the pool is weak by the sluggish movement of water and that the jets do not pop up.
  3. B

    Return water pressure too low

    The Hayward motor is SP2607x10. The century motor is UST1102.
  4. B

    Return water pressure too low

    Oh poo, The pool center that sold us the new one took the old one. I do know that it was a Hayward super pump. you are correct we only replaced the dry end including the impeller. the new motor is a century 1 HP with a service factor of 1.1(I've been doing a lot of research). I think the Hayward...
  5. B

    Return water pressure too low

    our 1HP Hayward motor died last week. prior to this all systems were working fine. we replaced it with a 1 HP Century motor. Everything works except the water flow coming back into the pool is not strong enough to pop up the floor jets or push very strongly through the side return. there is...