Recent content by AvockAdoo

  1. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    All of that sounds good! I will pull that thing and take photos in the morning. A few notes and questions: Miswiring: The guy said it was at his house when he moved in, used it for 8 years and when it leaked again this year he decided he didnt want to fix on it anymore. I think he replaced the...
  2. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    I think the way the motor is wired currently is white, black, red, green. I just swapped the red & black at the logic board to check - I think it was wired backwards. My thoughts - @RDspaguy please provide your analysis if you can! - is that the motor was wired wrong. Its now wired...
  3. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    Here are the photos I currently have - back of the pump, and a photo of the board. I will post a schematic photo on Sunday!
  4. IMG_8558.jpeg

    IMG_8558.jpeg

  5. IMG_8556 2.jpeg

    IMG_8556 2.jpeg

  6. IMG_8546 2.jpeg

    IMG_8546 2.jpeg

  7. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    I will double check the wiring - that I wouldnt know. If the previous owner replaced it and miswired it, that may be the case! I will do all of that testing on Sunday - unfortunately that is the next time I'll be able to test things out! I do have a multimeter - its this one: Commercial...
  8. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    I like your opinion the best! I'll swap the high & low speed wires and see what happens there. I dont want to mess with the board if I dont have to, and a new start capacitor is even cheaper than a relay replacement project. What would I do to test the motor start capacitor? The current flow...
  9. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    A bit more information here - pump 1 on level 1: 118V, pump 1 level 2: 118V (this is across the pump 1 connection wires). With the pump OFF I am still getting .5V across the pump wires. I think the other tech may be onto something with a relay sticking, but I am definitely open to any and all...
  10. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    Its hums right at the start and then quits, but I think the hum is coming from the board, not the motor. Almost sounds like a compressor airing up for 1-2 seconds and then it quits. Then it doesnt make any more sounds until it just starts up. Another spa technician thinks its the relays...
  11. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    I unplugged the ozone generator for now because it was causing an instant breaker trip. I'm planning on replacing it, but there's mixed reviews online of whether or not it would be worth it, or just run with it "deleted" Pump 1 is a two-speed pump, and Pump 2 is one speed. So I dont think I can...
  12. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    Originally posted this in the wrong thread - hopefully somebody in this one can help me out!
  13. A

    2005 Sundance 850 Marin pump 1 function questions & other small issues

    Hey all - first time poster here. I have done quite a bit of scanning, and I cant find the answer to my question so I figured I'd start here. I am new to this 2005 Sundance - picked it up for free in Denver "working" but leaking a bit. Got the leak fixed with a new pump fitting, but now I've...