Recent content by Andyroam

  1. A

    Intelliflo VS Overcurrent Error after filter mishap

    Thanks, I installed a motor (model 350105S), and replaced the shaft seal and gaskets using the saltwater kit from INYO pool (GOKIT32SALT), and it worked a treat. Andy.
  2. A

    Intelliflo VS Overcurrent Error after filter mishap

    Thanks, I'll get a motor ordered, hopefully that'll fix it. Andy
  3. A

    Intelliflo VS Overcurrent Error after filter mishap

    Hi TFP folks, My Intelliflo VS pump quits with an overcurrent error a few seconds after starting. This sad tale began when my spa was left running with heat, and while unattended, the top blew off the cartridge filter, allowing much of the water to escape. This lead to a waterfall of 95 degree...
  4. A

    Troubleshooting dead Pentair IC20 SWG and Power Center

    Thanks for your help - I replaced the dead IC20 with a new IC40 and it's running like a champ. I left a small donation to TFP as this saved me from calling out a pool tech and the inevitable sales people. Best, Andy
  5. IMG_3243.JPG

    IMG_3243.JPG

  6. A

    Troubleshooting dead Pentair IC20 SWG and Power Center

    Hi Jim, My pool's fairly irregular in size, but I'd estimate 12-13,000 gallons. That said, it's less than $100 to upgrade from an IC20 to IC40. Thanks, Andy
  7. pool.JPG

    pool.JPG

  8. A

    Troubleshooting dead Pentair IC20 SWG and Power Center

    Hi Jim, You're absolutely right, and on checking I get 240VAC across the 2 line wires (yellow & white). As per your suggestion, I disconnected the cell and put a new fuse in the Power Center. The green LED lights up and stays lit, with a reading of 27VDC between the red and black wires that...
  9. A

    Troubleshooting dead Pentair IC20 SWG and Power Center

    Hi All, My Pentair IC20 SWG appears dead with no lights. Looking through previous TFP posts, I figured I'd check the Power Center to check that it's getting power and passing that onto the IC20. First, checking the line input voltage, the transformer is getting 2 x 120VAC (yellow and white...
  10. board_02.JPG

    board_02.JPG

  11. board-01.JPG

    board-01.JPG

  12. A

    Lost connection to heater

    Hi Jim, Thanks, the Hayward manual gets us this far but then getting into the "E" mode for external control isn't explained... until I found an earlier thread on TFP... https://www.troublefreepool.com/threads/40209-Hayward-Summit-8TA-External-Controller-Setup ... which explains it all, and...
  13. A

    Lost connection to heater

    Hi All, First, I have to thank this forum for some advice I found here (using Google) about installing a Pentair Screenlogic2 wireless system to my pool controller - it worked so well that I registered here. Now to my issue: my pool control system (Pentair Easytouch/Screenlogic) no longer...