Recent content by andersonsa

  1. A

    Hayward H250 Pool Heater IF error code

    I have replaced the ignitor, and will spark and run for 5 sec or so before the error appears after three tries. I am leaning toward a total replacement seeing that seems to be consensus
  2. A

    Hayward H250 Pool Heater IF error code

    I did some more checking trying to locate the fenwal box and have attached some pics. The only thing I can come up with is the board. I can’t come up with any other boxes or anything else to take apart unless I am missing something. Thanks again
  3. B00119A6-342A-4DAE-BD76-EDE810C40BC0.jpeg

    B00119A6-342A-4DAE-BD76-EDE810C40BC0.jpeg

  4. 4E9EFFEF-44BC-4836-BB18-60393EB5A925.jpeg

    4E9EFFEF-44BC-4836-BB18-60393EB5A925.jpeg

  5. E1785C75-4889-4FA9-8092-6C53325C1F29.jpeg

    E1785C75-4889-4FA9-8092-6C53325C1F29.jpeg

  6. A05A532D-3577-4FDC-8E56-CCA3584096A1.jpeg

    A05A532D-3577-4FDC-8E56-CCA3584096A1.jpeg

  7. A

    Hayward H250 Pool Heater IF error code

    Gotcha, I will disassemble a bit tomorrow & take a look. I tend to agree with a replacement heater especially if the box is very pricy. But worth checking into. Thanks again
  8. A

    Hayward H250 Pool Heater IF error code

    Hello, I just checked for the flashing L.E.D light when trying to start my pool heater. The red L.E.D next to the word pool stays illuminated. The only thing that flashes is the red error code IF. Thanks in advance
  9. A

    Hayward H250 Pool Heater IF error code

    Yes, this is the manual i have. I will check on a flashing l.e.d tomorrow and reply back. Thanks for the info about the 500mv. I assumed it applied to the electronic as well.
  10. A

    Hayward H250 Pool Heater IF error code

    I have an electronic ignition. I am not familiar with the Fenwal box? i did replace the the ignitor. Thanks!
  11. A

    Hayward H250 Pool Heater IF error code

    Hello everyone. I am really struggling to find help to diagnose my 18 yr old Hayward H250 ED2 natural gas pool heater. I am getting the IF error code after the standard trying three times to light. We use our heater a whole lot. We also used it starting out this pool season until I started...
  12. A

    Rising PH

    oops, gotcha, I'll check that this evening. Do you think I need to raise my TA?? I really appreciate all of your help! - - - Updated - - - I'm not sure about a borate level?? If I raise my TA after dropping my PH will a higher TA make the PH more stable?? Thanks for all of your help!
  13. A

    Rising PH

    Thank you for the response. I just checked the TA after about 3/4" of rain this afternoon and it is 60 today
  14. A

    Rising PH

    Hi, I've been a BBB customer for a couple of years now and it is going great but I'm battling a rising PH level I can add acid to get it down to 7.6 and it gets it in check, but after 10 days or so I go back to 8.0 plus. I add acid and repeat the process. My TA levels stay pretty constant at 70...
  15. A

    Shock needed for pool opening