Recent content by Aerosfire

  1. A

    Intellichlor Water Temp Reading 0 Degrees - Cold Water Warning

    Signature Updated! First, an update. Since I connected the pump and IntelliChlor wires together at the same RS-485 terminal, the problem has not reoccurred. I am using Pentair Home and an IntelliConnect. It does show up as 2 separate devices in the app. I understand that manual is for...
  2. A

    Intellichlor Water Temp Reading 0 Degrees - Cold Water Warning

    The temperature sensor in the IntelliChlor is the one that drops to 0 degrees and throws the warning. Its not just getting a few degrees off because there is no flow, its exactly 0. It does only occur when the pump is off, but not immediately once the pump is turned off - several hours later...
  3. A

    Intellichlor Water Temp Reading 0 Degrees - Cold Water Warning

    I have an Intellichlor connected to an Intelliconnect via RS-485. My pump runs 7pm-8am. Once pump turns off, intellichlor turns “off” in Pentair app, but water temp still reports 85 degrees. Around 12-1pm (4-5 hours after pump turnoff) the water temp in the IntelliChlor changes to 0 degrees...
  4. A

    New build

    Have you seen any pictures or samples of the Moraine finish? I have not seen any pictures of it yet and am interested in it for my pool. Thanks!