Recent content by ack1961

  1. A

    AquaRite Goldline (AQM) not reading correct Salt Level - unable to calibrate Instant Salt

    Hey all, I've been through quite a bit of reading material on this site. There is some great information, but everything I tried has failed to isolate the issue. Symptom: Salt Level reads high (4,400ppm) [actual salt reading in pool is 3,400ppm]. Trying to calibrate using Instant Salt count...
  2. A

    Filter pressure low after sand replacement

    Problem solved. Bad sand. Replaced the Quikrete Pool Filter Sand with #20 silica sand and immediately my system returned to normal. 18PSI on Filter and holding steady. Water is perfect... Thanks!
  3. A

    Filter pressure low after sand replacement

    Thanks for all the replies!
  4. 20210403_162638.jpg

    20210403_162638.jpg

  5. 20210403_162551.jpg

    20210403_162551.jpg

  6. 20210330_073104.jpg

    20210330_073104.jpg

  7. A

    Filter pressure low after sand replacement

    Pool water is clear. Gauge does go to 0 when pump is off. 16 PSI in Recirc, 26 PSI in Filter Pool water tests fine via Pool-Master 5-way test kit. Ph/Alk are good. AquaRite Salt system shows 2800 ppm and generating Cl. Everything was working perfectly before I changed the sand. I changed...
  8. A

    Filter pressure low after sand replacement

    Hello all - been a member for a couple years and have learned a lot from the posts, but I am stumped with this current issue. I've been battling this one for about 5 days. After changing sand (5 years since sand replacement), I have an issue where if I'm running on Filter-mode, my starting...