Recent content by aceniza

  1. A

    Hayward Omnilogic/App connectivity Issues

    Update the app started to connect a little more reliably. I’m not sure what changed. I went ahead and changed the SSID on my Backyard access point on the 2.4GHz and connected the OmniLogic to that, just in case There were issues bouncing back & forth from the nearest indoor AP. So far it’s been...
  2. A

    How high is too high for FC?

    So up to SLAM level is safe for swimming? It didn’t need a SLAM, it wasn’t horrible. I just dumped a gallon and was like “yep, she gone be good now” like an idiot Overcast today with possible storms. At least it’ll dilute ?
  3. A

    How high is too high for FC?

    Opened up the pool lazily a few weeks ago. T-cell not cleaned and a HEAVY storm lead to some Algae. Pool rose about 4” from the rain. Yesterday I brought FC to 12 ppm with CYA at 50. Had 3lbs CYA in a filter sock thing and at the end of the night figured I’d dump another gallon of 10%...
  4. A

    Hayward Omnilogic/App connectivity Issues

    I did change the modem awhile ago. Maybe I need check ports and forward them. Didn't have to on the last one but who knows. I can't really plug in, the Access Point is full wireless and doesn't have any LAN ports on them. It's an outdoor POE AP. The strange thing is, even with the "Link Lost"...
  5. A

    Hayward Omnilogic/App connectivity Issues

    Hi Everyone, I've had the pool for over a year now, and the first year was absolutely flawless. Now, everytime I open the app, it shows that it says that the panel has lost connection to the router. I have a router nearby, as well as an outdoor access point about 15 feet away. Sending commands...
  6. A

    Hayward OmniLogic iOS App erratic

    Hey everyone, when I opened up the pool this year I noticed that the app had a huge update. All in all the UI was welcoming. I've noticed recently though, that when I start my pump, it goes through prime, and stays on high - if I switch it to medium, the flow is very, very low, and switching it...
  7. A

    Salt consumption

    amazing. I'm at 50% generation and still getting high chlorine, I need to set up a schedule to dial it in. Other than shocking after a party, the only thing I find myself doing is adding muriatic acid since I tend to run the pump often (spa spillover) and ph is always hovering around 7.7-7.8...
  8. A

    Salt consumption

    really??? I was told I needed to add approx a bag per month. Between my builder, his maintenance contractor, 2 separate cleaning services, and my local (and highly rated) pool store, it seems absolutely no one know anything about pools. Amazing. Looks like I need to test, possibly...
  9. A

    Salt consumption

    Just googled, I guess I should get a salt test, clean my t-cell, and check and/or recalibrate. still doesn't explain why it hasn't needed salt for 2 months.
  10. A

    Salt consumption

    Hi Everyone When I first joined the forum around June, my Hayward panel was reading salt really low, about 2400. Using the pool Calc, it called for about 1.5 bags of salt, I ended up dumping 2 bags in and it was reading around 4000. Since then, it's still reading at 4000. The water is...
  11. A

    Hayward T-cell 3 Flow Questions

    just an update, flipped the T-cell and no change. luckily I have a variable speed pump and found out that it doesn't start generating until 30% (low is 25%). I also managed to crack a union. I have major over-tightening issues. Luckily it's not leaking, but I'll have to change it out...
  12. A

    Hayward Omnilogic / Jandy Valve Actuators

    My PH has gone from 7.6 to approx 7.7 this week. I bought some muriatic acid, pool calculator tells me to drop it to 7.0 then aerate to raise it (to lower TA). But yes, I have a VS pump. I will look into the configuration you mention. I haven't messed with the automation outside of the...
  13. A

    Hayward Omnilogic / Jandy Valve Actuators

    Basically have the return go to pool, to spa, or 50/50 I like the spa to get circulated, but also like the flow from the pool jets/nozzles. This way I can keep the spa overflowing into the pool, but also keep the circulation in the pool pushing the surface towards the skimmer. I'm just weird...
  14. A

    Hayward Omnilogic / Jandy Valve Actuators

    I'm pretty sure the answer is "no" but here goes... Is there any way to set the valves partially? I have 3 valves, and only 2 Jandy actuators. I was told my control panel can only control 2 Jandy Actuators. I would love to be able to set my return valve between spa and pool.
  15. A

    Taylor F2006 / CYA question

    Thanks everyone. Just overthinking it haha.