Recent content by aalguire

  1. A

    Hayward H3001 Millivolt heater burners won't stay lit

    Natural Gas I get 170 millivolts across the pilot generator leads when the burners are lit with the jumper 350 Millivolts with burners off This is a brand new pilot generator
  2. A

    Hayward H3001 Millivolt heater burners won't stay lit

    The other odd thing is that the burners will light sometimes WITHOUT the jumper wire in place. I just tried again, bypassing each switch and limit, and I can get the burners to light, but after a few minutes the burners shut off. I was sure this was pilot generator not supplying enough power to...
  3. A

    Hayward H3001 Millivolt heater burners won't stay lit

    Thanks for your reply. I tried bypassing/jumping each component - on/off, temp, each limit, pressure switch, etc - and the unit still will not stay lit. No automation involved. This is as simple as it gets and still no luck
  4. A

    Hayward H3001 Millivolt heater burners won't stay lit

    HI I have had a problem for a couple of years with my Hayward millivolt heater. The burners won't stay lit consistently. When I bypass the pilot generator the burners light, but when I remove the jumper, the burners stay on for a while, or shut off immediately. I have replaced the gas valve and...