- Jul 24, 2017
- 171
- Pool Size
- 8400
- Surface
- Plaster
- Chlorine
- Salt Water Generator
- SWG Type
- Pentair Intellichlor IC-40
Having thought through it one more time, my theory that *maybe* female cable plug at the bottom of the IntellipH is the culprit actually doesn't hold together because, when I take the IC-40 cable directly to the EasyTouch, I get the exact same outcome, a dead cell with no lights, and we also know the Easy Touch cable connect is working fine because the voltage at the IntellipH output is good.I guess the only thing I've got left except a bad cell or cell cable is that maybe the female cable plug at the bottom of the IntellipH where the IC cable arrives could be defective? It doesn't feel like it screws in incredibly tight, but that as the failure point would be inconsistent with the fact that it worked perfectly for the first 10 days with the new IC-40, and likewise the recently replaced IC-20 never suffered any power loss at any time. The flow switch just failed on that and it was old enough that it seemed like prudent PM to just replace it. Going to check the inside portion of the pin connector that was an original focus as Lake Placid suggests, but even if I find something there, since I've got what I think is good voltage downstream from that point I don't think even a hidden, budding problem there could be the cause of the current IC is totally dead failure.
Last edited: