Pool is looking very good . Thought I would post test results
FC - 5.5
PH - 8.2 ( will add 11oz of 31.45% baume )
TA - 70
CH - 150 ( not sure if this is to high )
CYA - 70
SALT - 2400 ( will add 55 lbs of salt )
TEMP - 69
Pump has been running 24/ 7
SWG is in standby mode ( what should it be set at ?

IMG_0053.jpegIMG_0054.jpeg
 
Last edited by a moderator:
CH - 150 ( not sure if this is to high )
High is 450. You get so much rain it will likely drop anyway.
SWG is in standby mode ( what should it be set at ?
Enough hours or % to match the recent daily loss. It's probably 1 or 2 ppm for you, but will spike soon.

Your SWG can make 11ppm per 24 hours. So roughly 1/2 FC per hour. 2 ppm would be 4 hours or any math equivalent.

8 Hours art 50%..... 16 hours at 25%..... etc.