Search results

  1. P

    Intermittent no cell power/no cell power 2

    This is my 3rd board over the past 17 years and just put in last year. Started getting intermittent no cell power and no cell power 2 errors this weekend. Checked the k1 relay and no burn marks. I went ahead and resoldered the pin anyway. Can anyone tell me what this circled area on the board...
  2. Screenshot_20240501_094614_Acrobat for Samsung.jpg

    Screenshot_20240501_094614_Acrobat for Samsung.jpg

  3. P

    Hayward Pro logic high salt/amps SWG T-cell15

    I am an idiot. I had left the multimeter on ac voltage from measuring the yellow and orange wires. Reading is the correct 24v when switching to DC on thw multimeter. I went ahead and swapped out boards to a new board I had purchased last year just in case. To my surprise it had one higher...
  4. P

    Hayward Pro logic high salt/amps SWG T-cell15

    Was getting high salt/amps error yesterday with the numbers jumping all over before when in diagnostic mode before shutting down. I was getting a no cell power 1 error. I have soldered the k1 relay many times in the past. I was going through the Hayward trouble shooting worksheet and getting...
  5. P

    Help Me Confirm Failing Salt Cell - Hayward AquaRite T-9

    The pins inside the salt cell power cord.
  6. P

    Help Me Confirm Failing Salt Cell - Hayward AquaRite T-9

    I just went through a similar situation, My positive polarity was reading 3100 ppm and negative polarity was reading 2400 ppm. Took it to a local pool store to have the Hayward cell tested and unfortunately they bent the pins when connecting to the tester. I had a great outcome though as the...
  7. P

    Connecting Tristar 950 and 2 speed pump simultanewously on prologic PS4 controller

    I just had a tristar 950 installed and it controls my filter/in-ground pop ups. My waterfall is on a separate super II pump. I was looking to see if its possible hook up and run the waterfall with a 2 speed pump to have better control(lower output for sound) of the waterfall. I don't want to...
  8. P

    Anyone tried uploading / downloading firmware from Hayward GLX-PCB-MAIN boards?

    I went ahead and purchased a knock off version of the pickit3 from Amazon. I had the local hayward tech come out this past week and he upgraded my firmware from 4.20 to 4.46 on my main board to get better funcions/options out of my Tristar 950 VSP. I had picked up a spare prologic controller...
  9. P

    Tristar 950 wiring to prologic controller

    I have been trying to find out why my controller box/transformer has been running so hot since my new 950 vsp was installed last week. I replaced the transformer and still is hot. I was looking through the installation manual and stated the pump shoukd not be wired to the filter relays but...
  10. 20180730_171957.jpg

    20180730_171957.jpg

  11. P

    Prologic Electrical panel hot to touch?

    It just seems too hot. Can't hold my hand on the back of the panel where the transformer is for more than a second(165 degrees this am). Another call out to measure the temp of the box behind the transformer when the pump is running would be greatly appreciated.
  12. P

    Hayward prologic power supply wire connection

    just replaced my transformer last night. The two yellow wires go below the yellow 20 amp fuse. On my board, the wire on top of the transformer goes on top, right under fuse, the bottom transformer wire goes below that one. On the bottom right corner of the board, the four color connectors go...
  13. Screen Shot 2018-08-06 at 6.23.07 PM.jpg

    Screen Shot 2018-08-06 at 6.23.07 PM.jpg

  14. P

    Adding fan to ProLogic Control

    I have been in contact with hayward tech support just today regarding how hot my prologic electrical box/near where the transformer is. 160 degrees plus on backside of the cabinet. I asked them the operating temp of the transformer and they told me they are not authorized to give me the specs...
  15. P

    Prologic programming issue with new Tristar 950 VSP

    My pump installer was able to get the local Hayward rep/tech to swing by my house today and upgraded the firmware from 4.20 to 4.46. Now able to run all 4 timers and speeds amongst other options. :D
  16. P

    Prologic Electrical panel hot to touch?

    Have been working on my pool a lot after having a new Tristar 950 installed this week. My electrical control box is very hot to touch, particularly in the upper corner where the transformer is. I have not noticed it before. I tested the transformer outputs which should read 2-2.9 ohms. My...
  17. P

    Prologic programming issue with new Tristar 950 VSP

    No spa, thanks for the spa suggestion. i'll have to play with the settings.
  18. P

    Prologic programming issue with new Tristar 950 VSP

    I live in Arizona where we get these horrible afternoon duststorms. Just want more control with the timers and ability to run full speed to do a quick clean up to remove the dust/dirt. Currently running about 80% now as my high speed. I finally found a document that shows the firmware updates...
  19. Screenshot_20180804-202918_Gallery.jpg

    Screenshot_20180804-202918_Gallery.jpg

  20. P

    Prologic programming issue with new Tristar 950 VSP

    Just purchased and had a new Hayward Tristar 950 VSP installed last week. I have a prologic board(G1-011049e-1) running main software 4.20. I had this board replaced 9 years ago under warranty as it was originally an aqua logic. I have an aqua logic display. After install, I was only able to run...
  21. P

    pool volume question

    Thanks for the input!
  22. P

    pool volume question

    I drained and acid washed my pebble sheen salt water pool this past weekend. I was told that it was approximately 15k gallons. It is a free form play pool but the actual dimensions are slightly larger than the plans show (about 2' longer and 6" deeper). It is about 37' long with 3.5 /5.5 /4.5...
  23. P

    2 speed motor wiring help

    Thanks for the input. I'm gonna give it a go this weekend.
  24. P

    2 speed motor wiring help

    I finally purchased a 1.5 hp 2 speed motor to replace my single speed hayward super 2. I have an aqualogic ps-4 for control with an available aux2 relay. I understand the wiring schematic but want to know the correct way to combine the line in and common wires to the new relay. Should I splice...
  25. P

    pool pump replacement questions

    I understand the solar and in floor would require the high speed. We only use the solar one month on each side of the swim season. The 3/4 hp impeller would be for the waterfall/grotto pump. This is not attached to in floor system.
  26. P

    pool pump replacement questions

    I have a couple of pool pump questions before I buy. I am trying to lower my energy cost here in Arizona and the pool pump would be a good place to start. I currently have a 15k play pool with an inground cleaning system. I use a t-cell-15 for salt chlorination and c4025 cartridge filtration. I...