  1. L

    Aqua Rite Generator going bad??

    Hi everyone ... After taking resetting the board to T-15 and letting it run all day yesterday, the issue is resolved and all levels are now good so I won't be taking any further action. Thanks to everyone for your feedback and guidance!
  2. L

    Aqua Rite Generator going bad??

    Yes, it says T-15 on the label. I'm not sure how the board would have reverted to a T-3 reading? I will change it to T-15 and then retake all the levels again.
  3. L

    Aqua Rite Generator going bad??

    I'm actually running a T-15 cell. I don't know how it is showing T-3 on the panel. Maybe that's the problem right there? Typically, we run the T-15 during the summers here in the desert from 8a-4p, daily. I will take the cell into the local pool store to have it tested. Thanks.
  4. L

    Aqua Rite Generator going bad??

    Move the switch from auto to off and check all of the readings. 1300 63 31.3 0.0 35P -0 AL-2 r 1.59 T-3 Move the switch back to auto and recheck the readings. 1300 63 25.7 5.76 35P -1700 AL-2 r 1.59 T-3 Move the switch to off for a minute and then back to auto and recheck the readings. 1300...
  5. L

    Aqua Rite Generator going bad??

    Our motherboard for the Aqua Rite shows low salt and inspect cell. We cleaned the T-15 Cell and re-installed the cell. I held and reset the diagnostic button per normal procedure to reset the cell. The power light and generating light came on. Then after a few minutes there was an audible click...
  6. IMG_4619.jpg

    IMG_4619.jpg

  7. L

    Doheny Dolphin life span

    I have a Doheny Dolphin that is at least five years old and I bought it refurbished. It has always worked well but now it doesn't seem to be getting the pool as clean as usual. It is still getting the large debris and most of the silt but not all of the silt/sediment. We are using the folded...
  8. IMG_6367.jpg

    IMG_6367.jpg

  9. IMG_6368.jpg

    IMG_6368.jpg

  10. IMG_6370.jpg

    IMG_6370.jpg

  11. L

    Old Salt Cell

    Thank you!! :)
  12. L

    Old Salt Cell

    Hayward Turbo Cell T-15.
  13. L

    Old Salt Cell

    We recently put in a new salt cell. Is there any reason to hang on to the old salt cell? I vaguely remember reading how you can test your salt cells viability by using an old salt cell but I may have been dreaming!
  14. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    One more question. Could anyone recommend a submergible pump that doesn't break the bank? it is going to be $50 a day to rent one so I figure I might want to buy one I can also use in the future. Thanks again!
  15. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Hi there ... sorry to have taken so long, but just got our K-1766. Salinity reading was 5400. So, using the math you provided above = 2700/5400 = 50%. We recalibrated it to a T-9 per your recommendation a few days ago and it shows 3900 and no flashing lights. Our free-chlorine has been good...
  16. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Thank you - I just changed it to T-9. Funny thing is that when I did that, both the "low salt" light and "inspect cell" light stopped flashing. They are now off.
  17. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Thank you - And I'm assuming that if the calculation you show above holds true once we get the K-1766, then we're going to have to drain the pool a bit? Would it be a partial/half drain required or do you think it would involve a total drain? Thank you.
  18. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Also, I did take a water sample down to one of the local pool stores this morning. They got a reading of 4100 on salinity. If I end up having to purchase a new T-15 cell, can you please tell me a couple good sources where I can buy one? Thank you.
  19. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    We are ordering the salt test kit you recommended. However, in the interim, we purchased some strips from our local Leslie's just to have a quick look. The salinity was about 4500 using the strips. Our chlorine level is 4. At this point, does this sound like a problem with the salt cell or...
  20. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Thank you for the quick reply! Here is the info you requested: Report all readings when you.. Move the switch from auto to off and check all of the readings. 2700 57 31.6 0.00 12p -0 AL-1 r 1.59 t-15 Move the switch back to auto and recheck the readings. 2700 57 27.0 4.39 13p -2700 AL-1 r...
  21. L

    Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset

    Hello ... I have a pool in the CA desert. The Aqua Rite motherboard was replaced in August 2016 and the T-15 salt cell was replaced in May 2019. I did my routine check today of the salt cell due to the LED light was flashing. The cell was clean and I reset the motherboard to stop the flashing...
  22. L

    R0004 vs. R0014

    Thank you everyone!
  23. L

    R0004 vs. R0014

    Hello - When I went to reorder the PH tester chemical R0004 they didn't have it, the replacement is R0014. I have just tested using the new R0014 and my water is very pale lavendar. Does anyone know if it is the same quantities to test with R0014. I am using 44ml water to 5 drops of R0014. Thank...
  24. L

    Pool acid wash then refill

    No water softener. Plaster is 6 - 1/2 years old and isn't badly stained, except for the bottom step that are old pool vacuum used to go against and made a stained line all across the stair face. Maybe I need to rethink the acid wash at this time and wait until it is really horrible, and just...
  25. L

    Pool acid wash then refill

    Hello - Our calcium hardness is too high so we decided to get our pool acid washed after it is drained. The company doing it will also rebalance the chemistry when it is refilled. We have a salt cell so all I ever use is pool salt, acid, baking soda and conditioner. What order should we be...
  26. L

    Drain and Refill Pool

    Hello - It is time to drain and refill my pool due to high calcium hardness (my test kit is putting it at 1500). I decided to get the pool acid washed since it needs to be drained anyway (plastered 6 years ago). I live in the desert so I know I need to wait until the weather cools down in the...
  27. L

    High salt reading

    Ok thank you for all your help!
  28. L

    High salt reading

    Ok - thank you. I'm assuming I should leave the dial at 50%, then? Here are the revised diagnostic readings: 3200 76 25.2 7.07 48p -4000 AL-1 r 1.59 T-15