    Replacing check valve and a ball valve- not sure exactly how to do it.

    Great- will get the parts and give it a go next weekend. I did use the new O ring from the new valve. I think one of my screws on the valve is slighlty stripped- where that leak is coming from. Now it only leaks when the booster pump is on- so that is good. Thanks again.
  2. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    So i used the original valve cover- and it was doing the leaking then I put on the new valve cover that came with the new diverter. So anything caulk or a silicone sealant come to mind might work. When walking through your replumbing I thought of one that if i come out 2 inches more from the...
  3. IMG_4906 (1).jpeg

    IMG_4906 (1).jpeg

  4. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    So the width is different and not the height- also it was from a new 3 way valve and i took out the diverter in the valve(did buy larger part and cannibalized). I was able to finally get the diverter valve to shut- but it has to be precise. So i took off the actuator and replaced the valve in...
  5. old and new diverters front.JPG

    old and new diverters front.JPG

  6. old and new diverter top.JPG

    old and new diverter top.JPG

  7. Leak in valve cover.jpeg

    Leak in valve cover.jpeg

  8. Top view of Valve replacement.jpeg

    Top view of Valve replacement.jpeg

  9. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    I had yet to do the check and ball valve replacement and trying to buy parts. So in speaking to the pool supply guy and i was asking him about the vavle replacements. He thought the the check valve probably wasnt the issue as my pool equipment is some 3-4 feet above my spa and pool. He...
  10. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    I have done some digging with the various issues i am having. What it looks and sounds like is my diverter valve is not closing entirely when put into spa mode and i can hear the water going down to the pool pipe. I recently replaced the diverter valve with what i was told would replace it...
  11. Original Diverter.JPG

    Original Diverter.JPG

  12. Pool Diverter.jpg.JPG

    Pool Diverter.jpg.JPG

  13. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    So the ball valve does not close all the way either- this all came with the house i bought 10 years ago. So the ball valve closes off the spa- so the water only returns to pool. I have yet to use the ball valve in the 10 years i have had it but I feel i need to have one. It would be easier...
  14. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    I was thinking it would be easier to keep everything 2 inch- but wasnt sure the size of 1.5 inch was there for a reason. when the pool return is open so water goes to both pool and spa as spa has waterfall feature into pool- i was thinking it may be because the design wanted more water diverted...
  15. Image1024_1.jpg

    Image1024_1.jpg

  16. B

    Replacing check valve and a ball valve- not sure exactly how to do it.

    I have a leaking check valve that leaks back into my pool when i run the spa. I am new to the plumbing side but think I have the right areas to make the cuts and what i need to replace. Can someone take a look and see if this looks right. The pool return is on the left side and the spa return...
  17. B

    406A Raypak rattling noise in header

    sorry i am new at this- but can i take the header off from detatching the inlet/outlet access pipes as well as the 8 bolts where it attaches to the heat exchanger and just pull it out? Or will i need to cut out some plumbing pipes? Will that give me access to repair and replace parts in the...
  18. B

    406A Raypak rattling noise in header

    Thank you. Will give it a shot this weekend.
  19. B

    406A Raypak rattling noise in header

    My 406A has had a rattling noise in the header. It shuts itself down and I suspect the Unitherm Governor or bypass or both is the problem. I can't get the square retainer bolt out. Any suggestions? It is not in that bad of shape but had Leslie's pool come and he had a simple crescent wrench...
  20. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    Wanted to check one more thing and remove the burner tray and see what the technician has done with them- and if any of the burners look like the need to be replaced. But not sure what is the correct way to disconnect the gas valve. Here are 2 pics- one right on the outside of my heater then...
  21. unnamed.jpg

    unnamed.jpg

  22. IMG-4729.jpg

    IMG-4729.jpg

  23. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    do Raypak warranty company B and B pools in the bay area. my technician just wants me to buy a new heater from them. maybe the right thing but would like to have someone I know is raypak qualified to look at the heater - any suggestions from anybody. In the east bay San francisco. Thanks...
  24. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    Were you able to see a picture of the flame? hope that went through. I have a Robert Shaw 7000 DERHC gas valve. Can i just dial back the gas on that? Or is that getting above my paygrade? Thanks.
  25. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    In late 2020 I had my technician pull out the burner tray and clean the burners. After that is when these various problems started on the cycling and overheating i guess. Yesterday after cleaning the pilot assembly that seemed to work but I had my cover open- so cool air and oxygen were...
  26. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    So it looks like it works. My flames look high and yellow more than blue. My board LED looks weak which I think is due to heat but not s
  27. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    So my Flame when on is 8. earlier today i did scrub with wire brush the mounting bracket as well as the fork on the pilot. I didn't remove the tube and take it out I left it in the heater and worked around it. I also cut the green ground wire to stripped to fresh wire and screwed that direct...
  28. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    Thank you. I went through the fault history and have all Main Ingitition Failures and the 3rd one was No pilot sensed. all the rest1-10 were main ignition failures. Could insulating the High LImit switches help that? I would think it would give me an HLS fault. Do you know where i can get...
  29. B

    406A raypak heat shuts off after 5 minutses and keeps cycling

    Adding a little more here. I took a wire brush and cleaned the pilot assembly- the walls of as was some rust in there. The heater fired and worked for 45 minutes- got the spa up to 101 and then it started cycling again. I think maybe it is the grounding now but not sure why it would stop...