Recent content by kitamiman

  1. K

    Pentair Intelliflo VSF 011056 replacing vs 3050 - control cable question

    Thanks to all who replied. I realized that although the VSF 011056 does not have the screw on cable retainer on the pump, the cable that came with it (350122) does, and cable 350122 is also sold as a replacement cable for the vs3050. Thus, I think the cable is the same. Have not yet plugged it...
  2. K

    Pentair Intelliflo VSF 011056 replacing vs 3050 - control cable question

    Hi Jim, I have the new comm cable- re-running it from panel to pump is just one more job I was hoping to avoid... or at least postpone until I have more time.
  3. K

    Pentair Intelliflo VSF 011056 replacing vs 3050 - control cable question

    Ugh - sorry. Have edited my original post... New pump is Pentair Intelliflo VSF 011056...
  4. K

    Pentair Intelliflo VSF 011056 replacing vs 3050 - control cable question

    I am swapping out a dead Pentair vs3050 with a new Pentair Intelliflo VSF 011056. The original vs3050 control cable from the panel fits the control cable plug socket on the VSF, but it does not have the screw on retainer so I suspect it may not be exactly the same. Can I simply plug the...
  5. K

    Stabilizer in return - OK?

    Thank you very much for the replies. My pool is fully tiled with negative edge, so no risks to finish and no skimmers. I put 120 fl oz (by vol) in a brewing bag on the drain last night and it all dissolved by this morning, so as no one has suggested a risk to pump/intellichlor etc I guess I...
  6. K

    Stabilizer in return - OK?

    Typically, people suggest hanging the CYA in a bag in front of a return. I have found it very effective to put it in a bag/old tights on top of my drain, so water is pulled through it. My pool has two drains beside each other for safety, so water is also being pulled from the other drain when...
  7. K

    Pentair 011013 replacement with 011056

    Thank you for quick reply - that's great!
  8. K

    Pentair 011013 replacement with 011056

    My Pentair 011013 has died (corrosion). Does anyone know if the geometry on the latest version (011056) is identical? i.e., can I swap in the new pump without changes to the piping...?
  9. K

    Replacing Pool Pump -- Can't Find Correct Union

    Does he really have to drain? Surely he could simply put expanding plugs in all the returns, drains, etc in the pool (or perhaps only in those upstream of this pump....) I have used the Flexpvc internal fittings and agree one would probably offer a solution.
  10. K

    Intellichem with Easytouch

    Checking water in the flow cell was a good call; PH was higher than that of the water about a foot below the surface of the pool that I tested initially (my return feeds from main drains at deepest part of pool). Interesting - I wonder if PH is always higher at the bottom... Anyway, flow cell...
  11. K

    Intellichem with Easytouch

    I tested the pool. Will test the water in the cell, which does have pressure differential and flow. Power has been cycled but will recheck everything today. Thanks again.
  12. K

    Intellichem with Easytouch

    Thanks for that, but still no joy. I disabled the Intellichlor in Easytouch, but it is still not being controlled by the Intellichem. It just stays on all the time at the setting on the unit. Furthermore, I may have another problem. The Taylor PH test is clearly showing a drop in PH, (from 7.5...
  13. K

    Intellichem with Easytouch

    Hi Jerryt, The Intellichlor is working in the sense that it is running fine as a standalone unit. The config on the Intellichem is correct (Configuration/Hardware/ORP Control/ORP Control Doser Type [INTELLICHLOR]), and it seems to think it's in charge - displays dosing messages etc - when it...
  14. K

    Intellichem with Easytouch

    Thank you both for the replies. >>The intellichlor can be controlled by either the intellichem or the Easytouch, but not both... Not sure how one sets this up.... I have today checked all comport connections on Easytouch, Intellichlor, and Intellichem, which are all wired back to the com port...
  15. K

    Screenlogic dead?

    I have a Screenlogic 2 protocol adapter that I bought last year. It was always temperamental and difficult to 'hit' on the network, but apart from network issues it did work. After a 5-month absence it now appears to be dead; the red light is on, but the tiny green network light blinks once...