Recent content by coog61

  1. coog61

    Pentair Salt Cell "Green" but not producing Cl

    A belated update ... I contacted Pentair via the form on their site and after a week ... no response. I called ready for a battle and after explaining the issue and them seeing it was under warranty, they easily agreed to send out a tech to replace. Excellent.
  2. coog61

    Intellichlor temp issue

    Although the system is reading water temp of 60, the cell is still in cold water mode, not producing Cl. A separate thermometer reads 57. The cell is new as of Oct this year. Is it the temp sensor?
  3. coog61

    Pentair Salt Cell "Green" but not producing Cl

    Re: Pentair Salt Cell "Green" but not producing Cl Jim - in all the years with this pool (and all my cells), i've never had scale. - - - Updated - - - With Pentair, is it better to contact them via the form on their website or phone? I registered the cell when I bought it in March
  4. coog61

    Pentair Salt Cell "Green" but not producing Cl

    Thanks for the quick response. One thing I left out is that over a few days I went from 4ppm Cl to 0 running at 50%. The cell was new as of 3/18, so I will report it. This is the 5th cell in a 10 year old pool.
  5. coog61

    Pentair Salt Cell "Green" but not producing Cl

    Up to a few days ago, all was running well. Now while the "Good" Salt light on the Pentair IC40 is green and NO Errors, the control panel shows 0 ppm for salt. Not producing Cl. :(The PS (I know, I know) gave a reading of 3500 ppm and the TDS meter showed 2800 ppm. Any ideas? Strange that the...
  6. coog61

    Low water in spa

    UPDATE: I had a pool repair company pressure test the pool. They indicated that since the hard freeze we had this winter (hey, its Houston), they had seen a lot of plumbing issues. The test showed small leaks around some of the spa jets. When dye is injected around the jets you can see it get...
  7. coog61

    Low water in spa

    I’ve recently had water levels in the spa dropping over night and then not refilling when the pool starts. I have replaced the back flow valve. When I speed up the pump I will get a huge amount of air out of the spa valves. Any thoughts?
  8. coog61

    Thinking about LED lights

    I'm using a Easy Touch 8 control panel (8 yrs old) with the standard 500W white lights (which have failed). Generally what is involved in upgrading to LEDs? Other than the bulbs, any new equipment? Should I stay with Pentair? Thanks
  9. coog61

    Booster Pump Power Question

    I had pool repair guy check the pump. His verdict is that the pump is pulling 270 V. Thinks it's either a defective pump or something upstream. Any thoughts ?
  10. coog61

    Booster Pump Power Question

    There is a GFCI on the control panel. Not tripped and all other equipment working. The question is how a pump that worked with the wiring the photo is replaced with the same equipment, wired the same and doesn't work.
  11. coog61

    Booster Pump Power Question

    Thanks. I tried that, still no power and the pump started to get hot and smell
  12. coog61

    Booster Pump Power Question

    I'm replacing a Pentair LA01N booster pump with the same model. Pump on a 220 breaker. I've wired it just the same as the old pump. See pic of original wiring. So the only connected wires are the green ground and a purple in the L2 position. There was a another loose purple wire. Problem is that...
  13. coog61

    Replacing Pentair LN01N

    I'm about to replace a Pentair LN01N booster pump with the same model. Is there a reason I can't use the same flex hose that connect the current pump?
  14. coog61

    Blueberry tree stain

    I've had two Japanese blueberry trees next to the pool for 5 years with no issues. Recently it bloomed and then we were gone for a week. While we were gone a storm come though and left most of the blooms in the pool where they sat until our return. Where there were large mounds there is now...
  15. coog61

    Is my IC40 dead or fuse issue?