− | + | Taylor Technologies has [https://www.taylortechnologies.com/en/page/235/general-test-interferences videos on General Test Interferences] for: | |
− | *Calcium Hardness Test Interference - | + | *Calcium Hardness Test Interference - interference from copper and iron can cause a fading endpoint and some color changes before the final endpoint |
*Chlorine Test Interference - high levels of chlorine > 10 ppm can cause a false low or 0 chlorine reading. | *Chlorine Test Interference - high levels of chlorine > 10 ppm can cause a false low or 0 chlorine reading. | ||
*pH Test Interference - high levels of chlorine > 10 ppm can cause a false pH reading, usually bluish purple | *pH Test Interference - high levels of chlorine > 10 ppm can cause a false pH reading, usually bluish purple |
Latest revision as of 22:37, 29 November 2019
General Test Interferences
Taylor Technologies has videos on General Test Interferences for:
- Calcium Hardness Test Interference - interference from copper and iron can cause a fading endpoint and some color changes before the final endpoint
- Chlorine Test Interference - high levels of chlorine > 10 ppm can cause a false low or 0 chlorine reading.
- pH Test Interference - high levels of chlorine > 10 ppm can cause a false pH reading, usually bluish purple
- Total Alkalinity Test Interference - high levels of chlorine or bromine can cause reaction to change from blue to yellow instead of green to red
The videos show ways of compensating for the interference.