Difference between revisions of "Jandy AquaPure SWG" - Further Reading

Line 25: Line 25:
 
For example, at 50%, the box will say "Cell On" for 1.5 hours then "Cell Resting" for 1.5 hours. Then, there is a two minute off time, then the box will say Cell Reversing for 1.5 hours, then Cell Resting for 1.5 hours etc.
 
For example, at 50%, the box will say "Cell On" for 1.5 hours then "Cell Resting" for 1.5 hours. Then, there is a two minute off time, then the box will say Cell Reversing for 1.5 hours, then Cell Resting for 1.5 hours etc.
  
==AquaPure Resets to 35% Everytime it is Powered On==
+
==Troubleshooting==
 +
 
 +
===Jandy PDA not displaying Aquapure info===
 +
 
 +
Many AquaPure display problems seem to get fixed by powering the Power Center and Aqualink panel if connected off at the circuit breakers, waiting a few minutes, and powering everything back on.<ref> https://www.troublefreepool.com/threads/jandy-pda-wasnt-displaying-aquapure-info.194647/post-1715658 </ref>
 +
 
 +
===AquaPure Resets to 35% Everytime it is Powered On===
  
 
A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer.<ref>https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853</ref>  After discussions with a Jandy representative it was determined the problem was a bad board.
 
A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer.<ref>https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853</ref>  After discussions with a Jandy representative it was determined the problem was a bad board.
  
==Power Center Transformer==
+
===Power Center Transformer===
  
 
Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Currently, Jandy has part R0481400 which is the round transformer.  
 
Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Currently, Jandy has part R0481400 which is the round transformer.  

Revision as of 18:13, 16 February 2020

This article is currently incomplete. While this article is off to a good start, it still has room for major improvement. Until the article reaches its full potential, it will be hidden from search results.

Jandy AquaPure SWG

The Jandy AquaPure system consists of a Power Center and either a PURE700 cell or a PURE1400 cell. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine.

AquaPure cells connect with PureLink power center and AquaLink automation controllers.

AquaPure Cell Capacity

The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. You use the % generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need.

  • PURE700 - 0.625 lb./24 Hr. (283 gm/24 Hr.)
  • PURE1400 - 1.25 lb./24 Hr. (567 gm/24 Hr.)

Model Configuration

Both cells use the same Power Center box. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell.

If you are switching from the 700 cell to the 1400 cell the JL1 jumper needs to be reconnected.

Page 17 in the Jandy Power Center Installation Manual shows the location of the jumper.

AquaPure Cycle Time

The AquaPure has a 3 hour cycle time. The percentage setting will control how much the cell runs during the cycle.[1]

For example, at 50%, the box will say "Cell On" for 1.5 hours then "Cell Resting" for 1.5 hours. Then, there is a two minute off time, then the box will say Cell Reversing for 1.5 hours, then Cell Resting for 1.5 hours etc.

Troubleshooting

Jandy PDA not displaying Aquapure info

Many AquaPure display problems seem to get fixed by powering the Power Center and Aqualink panel if connected off at the circuit breakers, waiting a few minutes, and powering everything back on.[2]

AquaPure Resets to 35% Everytime it is Powered On

A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer.[3] After discussions with a Jandy representative it was determined the problem was a bad board.

Power Center Transformer

Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Currently, Jandy has part R0481400 which is the round transformer.

A member found that the new part fit perfectly with the same mounting holes. Even the High Voltage side wires were color coded identically. The only difference is the new part has a ground wire that was attached to the common ground.[4]