Difference between revisions of "Pentair UltraTemp Heat Pump" - Further Reading

(Created page with "=Pentair UltaTemp Heat Pump= The [https://www.pentair.com/en/products/pool-spa-equipment/pool-heaters/ultratemp_high_performanceheatpump.html Pentair UltraTemp] is a Heat Pum...")
 
Line 6: Line 6:
  
 
Pentair has a [https://www.pentair.com/en/knowledge-base/pool-spa-equipment/pentair-pool-calculators/heat-pump-calculator.html Heat Pump Calculator] to determine the appropriate size Heat Pump for your location.
 
Pentair has a [https://www.pentair.com/en/knowledge-base/pool-spa-equipment/pentair-pool-calculators/heat-pump-calculator.html Heat Pump Calculator] to determine the appropriate size Heat Pump for your location.
 +
 +
The UltraTemp Heat Pump can be controlled by Pentair automation - IntelliCEnter, IntelliTouch, Easy Touch. 
 +
 +
You can have both a MasterTemp gas heater and a UtralTremp Heat Pump on a pool. They are plumbed in line and hooked up to the IntelliCenter via RS-485 cable.  In the programming you have a choice of heaters for your spa and/or pool.
 +
 +
The automation is supposed to regulate temperature via the heat pump 1st - if it can not maintain temp it reverts to the gas heater. But after that it does not go back to the heat pump to maintain. You have to switch it manually.<ref>https://www.troublefreepool.com/threads/gas-heater-heat-pump-chiller.193934/post-1724624</ref>
 +
 +
Also, when in chiller mode Pentair forgot to link the temperature differential up to the chiller portion. So if you have a chiller set point of 87 degrees, and your temperature bounces back and forth between 88 and 87 degrees - your fan will cycle on/off, on/off, on/off until the temperature is a constant 87 degrees. That will eventually burn the fan motor up.<ref>https://www.troublefreepool.com/threads/gas-heater-heat-pump-chiller.193934/post-1724624</ref>

Revision as of 17:41, 28 October 2019

Pentair UltaTemp Heat Pump

The Pentair UltraTemp is a Heat Pump with models having 70,000 to 140,000 BTUs of heating capacity. Some models include a chiller capability.

All Models require 230V AC power and except for the 70,000 BTUs which requires a 40A circuit breaker, other models require a 50A circuit breaker.

Pentair has a Heat Pump Calculator to determine the appropriate size Heat Pump for your location.

The UltraTemp Heat Pump can be controlled by Pentair automation - IntelliCEnter, IntelliTouch, Easy Touch.

You can have both a MasterTemp gas heater and a UtralTremp Heat Pump on a pool. They are plumbed in line and hooked up to the IntelliCenter via RS-485 cable. In the programming you have a choice of heaters for your spa and/or pool.

The automation is supposed to regulate temperature via the heat pump 1st - if it can not maintain temp it reverts to the gas heater. But after that it does not go back to the heat pump to maintain. You have to switch it manually.[1]

Also, when in chiller mode Pentair forgot to link the temperature differential up to the chiller portion. So if you have a chiller set point of 87 degrees, and your temperature bounces back and forth between 88 and 87 degrees - your fan will cycle on/off, on/off, on/off until the temperature is a constant 87 degrees. That will eventually burn the fan motor up.[2]