gas valve

  1. D

    Hayward heater not firing

    I have a Hayward H400FDN heater that I've had for 10 years and this season it will not ignite. When I turn it on, the blower turns on, runs for a few seconds, then I hear the click it makes when about to ignite, but there's no ignition. The blower keeps blowing and it repeats that cycle two...
  2. O

    Jandy JXI400N heater says on in app, doesn't turn on except manually

    Hello Amazing TFP people. Weird issue with the heater that I am still scratching my head on... I think this is intermittent, which makes me think electrical or component related.... In the past few months, if I went to turn on the heater in the Aqualink app, the heater would come on in the app...
  3. J

    How to adjust manifold pressure on Jandy LXI gas valve

    Need help adjusting manifold pressure on Jandy LXI propane gas valve (see pics). I replaced gas valve and still have Ignition Fault so I used manometer to test input pressure (all ok), but my output pressure is running 7WC instead of 9WC. I removed the black plastic cap and tightened the plastic...