Search results

  1. P

    Noisy Pump 1 yr old

    US Motors Emerson is another large manufacturer of pool motors, their model EUST1102 would be identical to the UST1102. I'll let others maybe comment on which brand they might prefer, but from my personal experience haven't noticed a ton of reviews one way or the other.
  2. P

    Is poolsupplyworld.com legit?

    Dylan here from PoolSupplyWorld, thanks for your business with us bobtimms. I was able to locate your order in the system and it does look like your shipment was unfortunately mishandled, and lost. Good news is I can get another sent out your way right away. I'm reaching out to our warehouse now...
  3. P

    1/2 HP whisperflow...can someone confirm length?

    Pentair's website confirms that the length is 24.469" for the 1/2 hp WhisperFlo. Hopefully this helps!
  4. P

    LCD Screen on Pentair IntelliFlo gone bad

    The standard warranty is 1 year. It also depends on if you had it professionally installed or did it yourself. After a bit of research, it does look like you would need to replace the electronics module which is kinda pricey. But before doing that, try giving Pentair a call to see if they have...
  5. P

    time for new filter

    Hey Glenn, you've certainly got a handful of options! Sounds to me like you have pretty much ruled out a sand filter, because it won't do the job you are looking for. As far as DE vs Cartridge, it is really up to your preference. DE will filter better than a cartridge, but they are a pain to...
  6. P

    Pentair Hi-Flo Valve

    Hey Terry, this might be a simple fix. For some reason the spring is missing or not sitting correctly within the valve itself. This spring is what creates the tension on the handle. These valves are easily disassembled; you can open it up and take a look inside to determine if you can just...
  7. P

    New Hayward Ecostar Pump Stalled

    Hey Jeremy, welcome to TFP! I think this should be able to help! Do you currently have lots of back-pressure on the pump (possibly from solar panels?). Sometimes that can cause the pump to THINK its primed when it actually is not. Anyhow, try this to solve the problem! Have the Hayward...
  8. P

    Check Valve / Flow Meter

    Re: Check / Flow Meter Very interesting...I am going to look into this product for SURE! Thanks for sharing! :cheers:
  9. P

    HELP!!! or is this normal for the pump/motor

    What type of pump do you have? Is it on a timer?
  10. P

    Paramount Debris Cannister and MDX-R3 suction issues

    Here is the advice I got: "VGB laws resulted in the reduction of the velocity of water going through the main drain, so the PB is right – you shouldn’t be able to feel suction on it. No matter what, to ensure proper operation, the customer should throttle the skimmer down to ¼ of the way open...
  11. P

    Paramount Debris Cannister and MDX-R3 suction issues

    I've got a contact at Paramount..I will get in touch with him today and let you know what I learn about your system!
  12. P

    restoring straining cover tranperancy

    Agreed! :goodjob:
  13. P

    Pressure loss and fluctuation

    How high is your water level in your skimmer? That is probably the first thing I would check :shock:
  14. P

    Hayward Ecostar VS vs. Pentair Inelliflo VS Pump

    Honestly, both of those brands and models are solid! It is a matter of personal preference, and I am pretty sure the members here will be split down the middle. If you are installing (or planning to install) an automation system, then the biggest consideration is just making all of the...
  15. P

    Pump problems

    Pool store results are not always the most accurate. Jason is right about chemical levels and filtration likely causing the water issues. How do you manage your chlorine levels? If you have been using chlorine tabs/pucks for the last 5 years (and not replaced water recently), then there is a...
  16. P

    Pump motor replacement question

    Yes, the HP can change (higher)..just make sure you get a motor what will attach correctly. You will also want to buy a new 'go-kit' so that you can replace the seals when replacing the motor. I would not rule out craigslist completely, but be wary and ask lots of questions. I would hate to see...
  17. P

    New pump choice-- 2 speed or variable

    The low speed on a 2-speed pump will be 1/4 hp. Typically, this is plenty to get good circulation and skimming..as long as you optimize the directions of your returns. To test the surface movement, you can toss a ping pong ball into the pool and watch it float around the surface!
  18. P

    Need new pump, and I appreciate your suggestions

    Jason, I am looking at the owners manual for the WFDS-4 and it lists the pump at 115/230v ...Am I looking at the right thing?
  19. P

    Need new pump, and I appreciate your suggestions

    1) yes, you can replace motor..but that can still be expensive and your pump MIGHT still have issues. One benefit of changing JUST the motor is..plumbing from the wet end stays in tact. 2A) No you dont have to stay with 2hp. Before we can decide what pump is best...do you have any other water...
  20. P

    Need New Pump

    :goodjob:
  21. P

    How often to backwash a sand filter?

    If you are asking if back-washing daily is normal, then the answer is no. The frequency of back-washing will vary from pool to pool, based on bather load, debris falling into pool from nearby trees, etc. Keeping an eye on your pressure gauge is the best way to know when to backwash. How is your...
  22. P

    Another post asking for new pump help....please :-)

    I like Pentair, and think any of those would do just fine for you. If you get a SuperFlo, just make sure you get a dual speed.
  23. P

    Another post asking for new pump help....please :-)

    Either of those pumps would be an upgrade for you! As for the SWG, as long as it is not mounted vertically, the low speed should work okay for you. If you added solar, you would probably have to run the pump on high speed when solar is on...but you could test it on low and see how it works. It...
  24. P

    Help. New pump recomendations needed

    If you have a polaris 380...then you should have a booster pump running your cleaner. Are you sure you don't have a 360? (no booster pump requierd) As for pump, I second mas...I love the Pentair Intelliflo 011018
  25. P

    pump leak

    Did you change anything (hardware, settings, etc) before your pump started leaking? How old is the pump? Has the motor ever been replaced? If so, did you add new seals at the time?
  26. P

    Aqua Easy 20" too much?

    In my opinion, the problem with pump/filter combos is this... When something goes wrong with either the pump OR filter, you have to replace both. For that reason, I would suggest getting a pump and filter separately.
  27. P

    Uneven skimmer suction

    Re: Skimmer suction loss Personally, I have not dealt with this type of issue, but I HAVE read about it here on the forums. Another member used a Drain King on the skimmer side, and a snake from the valve near the pump. Apparently this loosened up lots of gunk and helped him get full suction again.
  28. P

    Uneven skimmer suction

    Re: Skimmer suction loss Did you have good suction in the vacuum? If so, it sounds like maybe its a circulation issue instead of an obstruction/suction issue. During the time that you saw a difference in debris collection, did you (or anyone else) change the positioning of your return jets?
  29. P

    variable or 2-speed

    Yes, the waterfall could run off the VS pump. An actuator would control weather or not your waterfall is on. SWG (or more accurately SWCG) stands for salt water chlorine generator. The ic60 you are looking at is a SWCG. In short, it automatically creates chlorine using salt. When working...
  30. P

    Don't let IDIOTS near your pool!!!

    Sorry to hear that, but sounds like you are taking the right approach! :goodjob: