    SWG Fixed with Water Change

    The power setting was at 3 and the volts went up to 25-27 with amps 7.2-7.7. I had a few readings with volts at 27 and amps at 5.9 which is when I thought I needed a new cell. On power 3, the amps should be close to 8. After the water change, I'm at 22V and 7.9a, which is where it was when new 2...
  2. F

    SWG Fixed with Water Change

    Chalk this one up to I have no idea. I have an autopilot SWG SC-60 which in AZ was working great at 25% and keeping TC 7-10ppm. Over the winter, the flow switch went bad and I had an algae bloom. Josh at Saltpoolguys.com, who is great, got me a new flow switch. I did the SLAM process and got...
  3. F

    Does using CO2 raise TA?

    I don't have any concern using HCl, but the thought of animating the process appeals to me and handling CO2 is less messy than keeping a bucket of acid hooked up to a Stenner pump. Given our water hardness, I'm really getting aggressive with keeping pH below 7.6 to keep me on the negative side...
  4. F

    Does using CO2 raise TA?

    I recently added borates to my salt water pool and as directed, I lowered my TA to 80. As expected, pH rise still occurs although more slowly with the borates. I add about 1/2 gal of 14% MA weekly to keep my pH 7.3-7.6 per Taylor 2006. My latest test results are: NaCl 3500 ppm, CH 320, Borates...