Search results

  1. N

    Electrical issues with entire Jandy system.

    I recently removed the solar panels from my roof. In doing so, I removed the valve actuator and temp sensor. I cut and removed the wires to the actuator. I now have NO action at the control panel! Other than hearing a slight hum (from the transformer?), there seems to be zero result from...
  2. N

    Controllers for Jandy ePump

    I recently purchased a Jandy variable speed JEP 2.0 ePump. I was under the impression that this would be controlled by my Jandy AquaLink RS, PDA. WRONG!! I am now told, by customer support at Jandy, that only a 4.0 version and newer AquaLink will run the ePump. I have a few options. I am...
  3. N

    Time for a new pump

    I have an 8 year old pool. When built, they installed a 2HP single speed motor. A few people have told me that this was "total over-kill". I have been waiting for it to die, so that I could justify spending the money on a variable speed pump. This morning when it kicked-on at it's set time, I...
  4. N

    Thinking about changing lights

    I have a plaster pool, about 8 yrs old. When built, we had Jandy lights installed; one in the pool, one in the spa. I think that they are called "color splash". ???? They are both failing. I have changed bulbs and the silicone gaskets, but MOST of the lamps are out again. Is it possible...
  5. N

    How much FC is safe?

    Hi folks. I cranked-up the run-time on my pump, in order to get more hours of solar heat generation this week. My plan was to raise the temperature for a birthday party this weekend. (Tomorrow) When I increased the run time from 4 hrs to 8 hrs, I didn't think to reduce the % of generation on my...
  6. N

    ?'s regarding Calcium Hardness and general water condition

    Hi Folks, I kinda took the winter off, and am now getting back into cleaning and testing my water. When I tested 2 weeks ago, I had zero chlorine, but everything else was pretty close. Today, I got the following results. FC=3.6 CC=0 PH=7.8 TA=100 CH=400 CYA=48 Temp=68 SI=0.12 I am not...
  7. N

    Small amout of recurring green algae

    I seem to constantly have a small amount of green algae. It is mostly found on the steps and in tight corners. (where the sweep doesn't go) Today's test results: FC=1.8 (I added16 oz. 12.5%chlorine) CC=0 PH=7.9 (I added 22 oz. muriatic acid) TA=110 CH=400 CYA=45 Temp=85 (we like it warm)...
  8. N

    SWG issues, again

    I am back again,:( after resolving a high salt level a while back. Chlorine production was perfect for a few weeks. I didn't do any chemical checks for one week, and came-back to find zero chlorine. The aquapure system was reading 4400 and giving error code for high salt. I tested my water and...
  9. N

    Stubborn TA

    I have a good test kit on order, expect it anyday now. In the interim, I am daily testing only CL PH and TA. I am having trouble getting the TA down. I will list measurements for the last few days, so that hopefully you will get a decent picture. 3/16/15 CL =5.0 PH = 7.6 TA = 210 Added...
  10. N

    SWG not making chlorine

    I have a Jandy AquaPure 1400. Newish cell. Only about one year since replacement. Newish back board. 8 Months +- I am always struggling with build-up of calcium in the cell. The salt content is currently too high. 3800-4000. The reading fluctuates. This is the first time that I have had the...
  11. N

    Jandy aqualink RS not turning off

    Hi Folks, Mike here. I have a pool/spa that is controlled by a Jandy Aqualink RS, with a PDA. Something malfunctioned today. The filter came-on at the scheduled time, but never turned off. When I realized that it was still running, I tried to turn it off myself. With the PDA set to "pool filter...
  12. N

    Calcium(?) buildup in my salt generator

    Mod edit: Please only make one post for each subject. People who can help will find it in whatever sub-forum you post it in. I have deleted you other topic. Thanks, moderator linen I have a Jandy aquapure 1400 that I have had to change because of cell failure. Though I admit that I probably...
  13. N

    Recommendations for equipment??

    Hi Folks. New here, looking for advice. I have an 8 year old plaster, salt pool that is ~11,000 gallons. The builder used a Jandy package, containing a CL 460 cartridge filter, a gas heater, an Aqupure 1400 and a 2HP pump. I have a solar heater and a pretty large spa. All of the valves and...
  14. N

    replacement bulbs for Jandy spa light??

    I have Jandy color quartz halogen lights in my pool and spa. I recently bought replacenemt silicone gaskets and bulbs for both units. The gaskets are correct, and the bulbs are correct for the pool light, but much too large for the spa light. I can not find anywhere online that gives the spae...