Search results

  1. J

    Very high salt reading.

    The voltage is still reading 24.02 with 9.89 amps. I've had the water tested twice by professional pool service companies and the actual salt ppm is 3700. I have reversed the polarity several times and I am still getting ppm readings that will vary between 4800 and 5200.
  2. J

    Very high salt reading.

    I had a pool service company come out and test. I don't know what test kit they used.
  3. J

    Very high salt reading.

    Already did that. In fact I have done this several time. No change.
  4. J

    Very high salt reading.

    I have a Hayward Pro Logic salt system that is running the GLX-PCB-PRO main board. About 2 months ago, I started to get low, then very low salt readings (2000 ppm then down to 1900 ppm). Naturally I added salt only to see the ppm go up slightly to 2100 ppm. I added one more 40 bag and when there...