Search results

  1. D

    IC40 Comm Link Error

    Thanks Jim. It'showing 3050 ppm with 73% pool and 0 for spa. Actual readings from 2 days ago showed salt at 3000 ppm and chlorine at 3.0. So it might be close. I'll let it run awhile and see if screenlogic changes. Thanks again!
  2. D

    IC40 Comm Link Error

    Yes sir that was it. Found the box, no comm wires. Powered everything down, ran 4 wires from the RGYB terminal to the RGYB comm port terminal of the ET, along with the pump and ScreenLogic (tight fit getting all those ends into the terminal). Buttoned it all up and works like a charm. Thanks...
  3. D

    IC40 Comm Link Error

    Thanks. I beleive you are correct. The ET comm port only has the pump and the ScreenLogic antenna connected to it. And I still can't find the surge card. Maybe it's behind something? I can hook wires into the ET comm port but where do I connect them to the SWG power center? Edit: I tried to...
  4. D

    IC40 Comm Link Error

    The SWG is working. All lights are indicating it is producing chlorine. If I pull up the Intellichlor on ScreenLogic it reads 0. If I change it, it will revert back to zero in a few seconds. On the EasyTouch I can adjust the level (i.e. 30% to 50% etc) but the IC40 does not change. I can...
  5. D

    IC-40 Communication Lost, but functioning properly

    Sorry to bump a 2-year old thread but this is exactly my problem as well. Pentair had me replace the sensor which has had no effect. Great info on this board has helped me a lot so I thought I'd create an account and post thanks. Going out to check my surge card now and see if there's any...