Search results

  1. B

    Jandy Controller Unresponsive

    This is what shows when your control boots up. It seems to be having issues pulling data from your power center. I'd have someone come out to check the cable between both for damage or loose connections. Worst case is that your controller is shorted out and needs to be replaced, but don't jump...
  2. B

    Jandy light help

    Who is your pool builder? I'd recommend contacting them first as they may be able to handle warranty in-house or have a warranty station on speed dial.
  3. B

    Broken water temp sensor disables aquapure?

    If the AquaLink system isn't getting a water temp reading, it assumes the pump isn't running. If the pump isn't running it won't allow operations like salt water systems and heaters. If you want to run your AquaPure salt system I suggest removing the 4-pin connection to allow it to run...
  4. B

    Jandy Aqualink PDA-PS6

    The PDA-PS6 kit includes 2 relays on top of the 4 relays that are always included with the power center box.
  5. B

    Aqualink

    Hello CK, The Jandy PDA system is not compatible with the new iAquaLink. You would want to go with a standard RS-PS8 Pool and Spa Combo system with Rev R (comes standard) and then purchase the IQ900 on top of that. If you want to add a secondary wireless controller for the house so that you can...
  6. B

    IAuqalink is Offline

    [attachment=0:30znfaue]all-button comm ts.JPG[/attachment:30znfaue] Check voltage between pins 1 & 4. You want about 8-10 vdc. - If this checks out, check continuity on your wires by tieing pin 2 to pin 1 and pin 3 to pin 4 on one end and test at the other. It'll either be a bad wire or...
  7. all-button comm ts.JPG

    all-button comm ts.JPG

  8. B

    Variable Speed Pump help

    For an easier installation you would want to use a 2-speed relay for your low speed, connected to Aux 2, with dip switch S1 #2 in the ON position. This will guarantee that you will not run into any problems.
  9. B

    Jandy Aqualink tri-sensor adapter

    AKC13 boards are the old style boards where all your connectors were on the top of the board with the digital display on it. Standalone (grey plastic box) or PureLink (behind AquaLink PCB). The NexGen AquaPure boards have the connectors on the front of the pib (mounted in back of APUREMs and...
  10. B

    Pentair or Intermatic... or something else for automation?

    Re: Pentair or Intermatic... or something else for automatio With AquaLink RS Rev O or newer or PDA Rev 4.0 or newer, you may run your comm wires direct to the pcb without needing the Intellicom II. Yellow to pin 2 and green to pin 3 on your RS485 terminal.
  11. B

    Aquapure 1400 - new sensor, adapter board, salt reading low

    Re: Aquapure 1400 - new sensor, adapter board, salt reading You should be able to install it without the tri-sensor adapter. Usually the old systems don't need 'em.
  12. B

    Any one have Jandy Iaqualink?

    PDA-PS6 (equivalent to AquaLink RS6 Pool and Spa Combo) Revision 1.2. Right now because the IQ900-PDA upgrade isn't available yet, you want to go with the IQ900-RS. This will upgrade your system to an AquaLink RS8 Pool and Spa Combo Revision R. This will allow you to support everything up to the...
  13. B

    Any one have Jandy Iaqualink?

    LOL! Beat me to wrapping it up. Doing this from work so I had to stop a couple times while I was typing it up.
  14. B

    Any one have Jandy Iaqualink?

    2 ways that you can check: - open up the power center and gain access to the backside of the board. The white sticker on the chip will tell you what revision you have (post it here if you need help figuring it out) --OR-- - if you have an All Button control: MENU -> SYSTEM SETUP ->...
  15. B

    Jandy Spa Side 4 Button Control Replacement

    You'd have to replace the entire thing, control and wire. They come as a whole piece. I've never installed one before so that's about as far as my knowledge goes on that.
  16. B

    How do you control a pentair intellibrite?

    Unless the software in the control system is written to set or control the light properly you'd have to manually switch it on and off to get the desired color or effect.
  17. B

    Jandy Aqualink tri-sensor adapter

    Sorry lungs, never saw your post for some reason. Has everything been resolved? Does your system display your salinity level accurately?
  18. B

    Polaris 360 only does edges in shallow end

    Have you considered trying the Polaris 360 PosiTrax tires for smooth surface pools? http://viewer.zmags.com/publication/8cf ... f3a979/266
  19. B

    Jandy Aqualink RS problem - Shuting down

    On the backside of your aqualink board there is a transformer connection that may be loosely connected or may have a loose wire like what PoolGuy said.
  20. B

    Jandy Gas Heater Rapidly Switching On and Off

    What's the model number of the heater?
  21. B

    Will jandy aqualink run Hayward ecostar.

    The software wasn't written to support a Hayward EcoStar. You would have to jerry-rig it to use auxiliaries to activate certain speeds.
  22. B

    Jandy Aqualink Weird Problem

    Here's what happens: NORMALLY, to get the heat pump options to show up, you need to hook up a 2.2k ohms resistor in the solar sensor sockets. If you actually have a solar sensor hooked up, test it. They are 10k ohms sensors. If for some reason the sensor is failing or not displaying the proper...
  23. B

    Jandy Heat pump - low pressure REF fault

    Good to know. Thank you Jeff.
  24. B

    Any one have Jandy Iaqualink?

    The upgrade kit you want is the IQ900-RS. This comes with a new 50-pin cpu board, Rev R chip and iAquaLink device. This upgrade will turn your system into an RS8 Pool and Spa combo if it is not already.
  25. B

    Aqualink with new pool question.......

    The new systems, IQ904-P or IQ904-PS are only available as RS4 Pool and Spa combo systems w/ 4-relay size boxes. If you want more auxiliaries, you need a bigger box. This is why they are starting with something else and then "tacking on". At this time, the PDA version of the iAquaLink is not...
  26. B

    iAqualink and RS12?

    By default the iAquaLink kits (IQ900 and IQ900-RS) are RS8 Pool and Spa Combo systems. Some cases, the dealer that's installing it will have it flashed before coming out and installing. If not done through a dealer, it needs to be brought in to a local dealer to have sent to us for flashing. We...
  27. B

    Jandy One Touch control

    If you're system is up to date try the AquaLink Touch (Rev Q or newer) or the new iAquaLink (Rev R or newer). These controls may be more of what you're looking for as a fellow tweaker. I do see where you're coming from though with the constant button pressing though.
  28. B

    Polaris 280 tail sweep inop

    Open up the cleaner and check the water management system for obstructions. It can happen often if you have small debris. Debris will get caught inside the cleaner and can plug up certain parts of your water management system.
  29. B

    Jandy Aqualink tri-sensor adapter

    What is the firmware revision on your AquaPure? Press and hold UP+DOWN+SALINITY TEST buttons until you get the revision number. If you have Rev 02110A10 did you remove the jumper?
  30. B

    Polaris 280 Track kit

    Polaris p/n: C15 -- 280 TankTrax Conversion Kit Comes with: Track Tension Adjustment Guide, Bottom Housing, TankTrax, Axle