Search results

  1. J

    1 yr old Goldline T-Cell-15 now always says No Flow

    Thank you for the replies. Filter pressure is usually 15-18 psi. And usually tops out at 22 when needs a backwash, but since have not backwashed since beginning of the season and pressure at 18 psi, I backwashed and still same result. Running at full speed and feel good pressure at input jets to...
  2. J

    1 yr old Goldline T-Cell-15 now always says No Flow

    Just over a year ago I replaced my Goldline T-Cell-9 with a Goldline T-Cell-15 which has worked great but now the control panel always shows No Flow so it is not generating chlorine. I have tried re-plugging it into the control panel and completely powering off/on the control panel but still...
  3. J

    Another Aqua Rite Reading "HOT"

    Yes, it shows its a T-9. I like the idea of less pump time with a T-15. Can I hook up a T-15 to my existing T-9 controller? Or do I need to replace the controller box as well?
  4. J

    Another Aqua Rite Reading "HOT"

    Yes it is 8 years old - from 2010.
  5. J

    Another Aqua Rite Reading "HOT"

    Just emerged a couple weeks ago from a cold temps that kept my 2010 SWG reading "COLD" and now, after some normal temps and getting salt in the 2800 range, it's reading "HOT". From another post, I see that it can be helpful to capture the readings to further diagnose: 1. Temp - 222 2. Cell...
  6. J

    pool pump makes humming noise and does not pump

    Just want to add that I, too, found one day that turning on my pump I just got a humming noise and, after making sure that it was adequately primed and still would just hum and not pump the water, I searched and found this thread which suggested the probably cause was the capacitor. I followed...