    Booster Pump Seal Leak After Motor Replacement

    That was it. I had the rear seal installed backwards. Pulled it apart this afternoon and the Polaris was back working in less than an hour. Thanks for the help!
  2. R

    Booster Pump Seal Leak After Motor Replacement

    I'm going to pull it apart this week and recheck the seal installation direction. The spring-y seal may be installed backwards. The impeller seal really only goes in one way; but, I'll check that one, also. I'll let you know what I find. Thanks
  3. R

    Booster Pump Seal Leak After Motor Replacement

    Mark, Thanks for the reply! It's coming out of the shaft area right around where the impeller is located. It must be the seal. The only instruction that I had was YT video; but, it seemed straight forward. Is there a secret to the seal installation? Can the seal faces get wet and be reused? Is...
  4. R

    Booster Pump Seal Leak After Motor Replacement

    I replaced my 3/4 HP Polaris booster pump motor with a B625 A.O. Smith and ordered/used the Go-Kit 71V-9 for the seal and O-ring replacements. When I lined the pump back up, there was a large continuous leak from the seal area. Mind you, the booster pump was not even running. The leak was from...