Search results

  1. wireform

    SWG Install and Opening Help

    When you initiate a slam you add what poolmath advises then check it 15 minutes later to see if you hit the slam level. If not add to reach the slam level again. Rinse and repeat till the first time slam level is achieved. Then you can take a 3 hour breather and Check/add back what's missing to...
  2. wireform

    Hello- owner of an above ground pandemic pool

    Here's for your reading
  3. wireform

    Circupool Core55 or RJ60?

    What he ^^^^^^^ said. RJ60 would be my choice.
  4. wireform

    Is there such thing as too much filtration?

    The million dollar question not asked yet is how are you testing. Before wasting more $$ get a good test kit And read
  5. wireform

    parts and installation of no-brand pump

    Assuming it's designed to fit 1.5" internally you would need pvc primer and glue to make it work.
  6. wireform

    Time for a new NG heater

    What are you comparing it to with your "load heater" remark
  7. wireform

    Let’s see your water after removing winter cover!! **RESURRECTED FOR 2025!**

    Snaped this picture while the guys were man handling the winter cover. Less then 2 minutes after being uncovered.
  8. Screenshot_20250426_224357.jpg

    Screenshot_20250426_224357.jpg

  9. wireform

    RJ60 plus up and running

    How many hours a day is the pump running.
  10. wireform

    How to keep pool water full?

    https://amzn.to/42pFHm7
  11. wireform

    How to keep pool water full?

    https://a.co/d/eossaUt
  12. wireform

    When to replace and where to buy Jandy CL 460 Filters

    Not the usual to replace filters yearly as many have them for several years without a problem. They're a good size and shouldn't need to be cleaned more then twice a season. Some have a spare set to switch fast and clean the dirty set afterwards for the next swap.
  13. Screenshot_20250423_011941.jpg

    Screenshot_20250423_011941.jpg

  14. wireform

    HELP! Just moved in and opened pool. YIKES!!! Where to even start?

    The slam will be expensive. I'd drain half to be left with 30 when refilled.
  15. wireform

    Looking for recommendations of SWG upgrade

    I highly recommend circupool RJ series.
  16. wireform

    Replace Pentair MicroBrite light

    Yes you can do it with the water level as is. There's water there all the time for the cooling aspect. Make sure to shut the circuit breaker before all and anything.
  17. wireform

    Screwdriver down skimmer

    It won't pass the first 90 bend. With water in the pipe it will look like it is not there. Vac out the water from the skimmer end and then proceed.
  18. wireform

    Localised itching on back - from the jets?

    CYA will come down on it's own between the heat and the time duration. The bigger issue is where the CYA is really at.
  19. wireform

    Draining a fiberglass pool safely

    Make sure you have a good delta T before the no drain exchange and follow the instructions to the end.
  20. wireform

    How to clean Polaris p95** filters?

    If the mesh is tearing then it's too fine and can't handle the pressure from the pump. For early in the season with heavy debris that is common. Just a FYI you can put a bead of crazy glue on the plastic where it tore from and then bring the mesh over it. Watch it absorb and tap it down with...
  21. wireform

    Pentair Filter tore and pool lost 70 percent water night

    Perhaps the clamp wasn't for this filter but worked until the clamp broke through the shell. As was said before me it's new filter time.
  22. wireform

    Fun weekend cleaning the pool and filter

    https://a.co/d/98R8wLQ
  23. wireform

    This mornings numbers

    The PH isn't accurate with an FC above 10.
  24. wireform

    How to clean Polaris p95** filters?

    I've never had what you describe, fill in the blanks.
  25. wireform

    Fun weekend cleaning the pool and filter

    Just screenshot all the pics and post those.
  26. wireform

    Why is FC still zero?

    Assuming your pump is running 24/7 at good decent rpm ?
  27. wireform

    Draining Pool

    As it has been said before me that 5.5 is skirting with danger for the CYA you have, get it up to 10 and keep it there.