Hi I have a 6500 gallon salt pool.
I noticed the chlorine levels were getting really low so I replaced the salt cell with the same model, a Hayward T Cell 925.
I can see that’s it’s working because there are small bubbles coming from the water jets and everything looks good on the aquarite control board.
I tested the water and the chlorine was really low so I’ve turned up the percentage dial.
I ended up going to 100% and the chlorine is still crazy low.
I took a sample of water to a shop
pH 7.6
Alk 69
CYA 71
FAC 2
TAC 2.6
CH 306
Pho 0
FE 0
CU 0.1
Salt 3200
Water sample was taken from the return jets.
Any ideas why it’s so low? With a new salt cell I should be making lots of chlorine especially with it set to 100%.
I’m in Orlando and the water temp is 87ish
Thanks
I noticed the chlorine levels were getting really low so I replaced the salt cell with the same model, a Hayward T Cell 925.
I can see that’s it’s working because there are small bubbles coming from the water jets and everything looks good on the aquarite control board.
I tested the water and the chlorine was really low so I’ve turned up the percentage dial.
I ended up going to 100% and the chlorine is still crazy low.
I took a sample of water to a shop
pH 7.6
Alk 69
CYA 71
FAC 2
TAC 2.6
CH 306
Pho 0
FE 0
CU 0.1
Salt 3200
Water sample was taken from the return jets.
Any ideas why it’s so low? With a new salt cell I should be making lots of chlorine especially with it set to 100%.
I’m in Orlando and the water temp is 87ish
Thanks