Recent content by usnavystgc

  1. usnavystgc

    In Floor Cleaners and Pressure Question

    I think you guys are right. I think I'll have to get up off my lazy butt and clean the filter more often. :)
  2. usnavystgc

    In Floor Cleaners and Pressure Question

    Good news on the home front. I cleaned the filter, added new DE and let it run. The pressure went down to 23 and the flow rate increased notably. All of the in floor cleaners are working well and the pool is sparkling clean. Thanks for all your help.
  3. Pool Pic2.jpg

    Pool Pic2.jpg

  4. usnavystgc

    In Floor Cleaners and Pressure Question

    You know, I never paid attention to that. Right now I have a dirty filter and I plan to clean it this weekend. I will have to check it again after I clean the filter.
  5. usnavystgc

    In Floor Cleaners and Pressure Question

    That def looks like the pump. The pressure varies between 23 with a fresh clean filter and 29 dirty filter. By high head pump, do you mean high pressure?
  6. usnavystgc

    In Floor Cleaners and Pressure Question

    Here's some pics of my motor and pump.
  7. IMG_20160907_173045.jpg

    IMG_20160907_173045.jpg

  8. IMG_20160907_173016.jpg

    IMG_20160907_173016.jpg

  9. IMG_20160907_173314.jpg

    IMG_20160907_173314.jpg

  10. usnavystgc

    In Floor Cleaners and Pressure Question

    Proavia, Thanks for the link to Pool School. I'm not the original owner. The diverter valve gearset has recently been changed (within the last year), the actuator valves were not replaced because they were in great condition. Many of the in-floor heads have been changed within the last year...
  11. usnavystgc

    In Floor Cleaners and Pressure Question

    Thanks for the quick responses. Not sure of the make and model of pump (AZ sun wore label away) but 1.5hp is stamped on it and as I stated it is about 20 yrs old (so I'm guessing its lost some flow rate/pressure). The in floor cleaning system is A&A. Chiefwej, Can you send me the info on...
  12. usnavystgc

    In Floor Cleaners and Pressure Question

    Hello Everyone, I have a kidney shaped pool (about 10,000 gals) with 14 pop ups and 3 side jets (5 stations). The pop up heads in the shallow side work great but, the one station in the deep end seems to have a design flaw. For one, there are 4 heads in that station causing a large pressure...