    Hayward H400FDN Ignition Failure

    I had an opportunity to take a quick look at the heater last weekend. I was able to use the resistor/diode combination to get the heater running which tells me that the problem is definitely being caused by a rectification failure. I let the heater run for an hour in order to heat up the hot...
  2. S

    Hayward H400FDN Ignition Failure

    Thanks for the words of caution and that great link. I am an electrical engineer by trade so i understand most of the risks of messing with electricity and flammable gasses. I hope to be able to find the root cause this weekend by measuring the current for the flame sensor circuit like...
  3. S

    Hayward H400FDN Ignition Failure

    Is there a logical way that I can test this theory out? I have access to meters and a scope? How is the circuit formed, does it originate at the flame sensor board and terminate to a ground through the flame? Is there a way to bypass or fake it so I can rule this out? I also think that...
  4. S

    Hayward H400FDN Ignition Failure

    Thanks for all of the responses. I did check the gas orifices and they were clean. My heater is less than one year old and I am now suspecting a small leak like noted in the posts above. I did replace the flame sensor so I know that wasn't the problem. I will take the unit apart this weekend...
  5. S

    Hayward H400FDN Ignition Failure

    I am also having the IF issue. I took everything apart today to a take a look and everything looks fine with no spider webs. I did not take of the the jets to look at them when I had the burner tube off so I will need to do that tomorrow. Mine starts up with all the clicking and I can see the...