Recent content by Scarsnhoos

  1. S

    Hi limit 2 fault and a water SW open fault code

    Thanks for your advice. I will get the parts ordered and let you know the outcome.
  2. S

    Hi limit 2 fault and a water SW open fault code

    Okay thanks that makes sense. I wanted to find out what caused the pvc pipe to swell before I simply repaired the pipe. Otherwise the new pipe could do the same thing again. When you mention safety shut offs in the heater, are you talking about the unitherm governer located in the header and...
  3. AF39A5D0-96B9-4D46-880F-87F636BBD8B1.jpeg

    AF39A5D0-96B9-4D46-880F-87F636BBD8B1.jpeg

  4. 1603D6DA-53FE-44DC-BEDF-44FF9010B710.jpeg

    1603D6DA-53FE-44DC-BEDF-44FF9010B710.jpeg

  5. S

    Hi limit 2 fault and a water SW open fault code

    I think I may have found the culprit. Just went through the whole system inch by inch, and found that there is a flapper valve missing that is connected to a sight glass at a junction in the system plumbing. Pictured below I replaced this sight glass/flapper valve about 6-9 months ago due to a...
  6. 1C4A7564-DE3F-4F4A-AE3E-E77DA0C10C49.jpeg

    1C4A7564-DE3F-4F4A-AE3E-E77DA0C10C49.jpeg

  7. AEE3CE36-2DDC-4F2D-8577-D39B55386B56.jpeg

    AEE3CE36-2DDC-4F2D-8577-D39B55386B56.jpeg

  8. S

    Hi limit 2 fault and a water SW open fault code

    My finger is pointing to the hole in the second picture.
  9. 31E5CD0F-ADE0-4F29-9B3E-7BD0DCC21287.jpeg

    31E5CD0F-ADE0-4F29-9B3E-7BD0DCC21287.jpeg

  10. 83244B61-6727-418D-9BB7-73FC0428813B.jpeg

    83244B61-6727-418D-9BB7-73FC0428813B.jpeg

  11. S

    Hi limit 2 fault and a water SW open fault code

    Sorry I should also add it didn’t go back to its original shape the pipe is still swelled up. The expansion of the pipe is permanent.
  12. S

    Hi limit 2 fault and a water SW open fault code

    It is schedule 40 pipe, all the elbows are as well. I agree pvc isn’t that flexible so it took a lot of heat and/or pressure for it to expand like it did. I will send a picture this evening.
  13. S

    Hi limit 2 fault and a water SW open fault code

    The heater is 8 yrs old. The pipe is pvc that is leading up to the inlet header and connects to it. I will post a picture this evening when I get home. I have checked “By feel with my hand” both the inlet and outlet pipe of the heater for water flow and both seem to be operating normally. There...
  14. S

    Hi limit 2 fault and a water SW open fault code

    I have a Rheem model # P-M406A-EN-C gas heater for my pool and spa. Running the spa the other night and heard a water spraying sound. Checked heater and discovered that the inlet pvc pipe had swelled up to almost 2X it’s normal size just at the intake of the Heater and had popped a small hole...