Recent content by SammyPoolGuy

  1. S

    ET-1, ET-3 timers not controlling the main pool pump

    Your guess would be RIGHT! So I had a pool tech come out and he explained how the box, breaker, relay and timer all worked together. He found that: 1. The breaker for the booster pump relay was not fully contacting the metal brick behind it. Part of the plastic that holds it in place was...
  2. S

    ET-1, ET-3 timers not controlling the main pool pump

    I couldn't find any threads on Innovative Pools Inc ET-1 and ET-3 timers. Filter Pump: Starite Max-E-Glas II Booster Pump: Pentair Boost-Rite universal booster pump Timers: Innovative Pools Inc ET-1 (I've recently swapped in ET-3s to try and fix the issue) Issues: - booster pump stays on...