Recent content by Sailorkane

  1. S

    Aquatrol assistance

    Well, pool shop tested the cell and it came up bad. Darn. NIB.
  2. S

    Salt Cell DIY Repair?

    There have been some salt cell threads on repair and construction of the Hayward salt cells. I have a Hayward T-15 that I bought NIB on the internet, but it has some kind of internal failure. I'm trying to get Hayward to stand behind it, but so far no joy. The salt reads low (900) when the...
  3. S

    Aquatrol assistance

    Voltage stays steady. Amps stay steady, but only until it decides there is not enough salt. Salinity has been checked by pool company and our very reliable separate tester. I put the jumper on and put it to T5 setting and it thinks salt is 1900. Put it to T15 setting (its actually a T15) and...
  4. S

    Hayward AquaTrol jumper

    Hello Guys. Not to hijack an old thread, but I have exactly the same issue. My board is the same G1-015005-10 Aquatrol unit, r1.47. It worked fine with a T5 for a long time then the T5 died and I got a T15. I jumped J4 by soldering pins and putting a jumper on the pins. Tested with a meter...
  5. S

    Aquatrol assistance

    I have Aquatrol r1.47 RJ. It has been working for years with a T5, which finally died. I got a Hayward T15 and jumpered J4. It thinks the salt is 900 (its really 3000). My numbers are 93, 27.4, 3.22, 100p, -900,AL-7,r1.47. The plumbing is the same as has worked for years with the old T5...