Recent content by Richard2020

  1. R

    Pool heater leaking

    Second company inspected the pool and concluded that no internal corrosion inside the heat exchanger; thickness confirmed; internal leak not readily found;
  2. IMG_20240329_132747390_.jpg

    IMG_20240329_132747390_.jpg

  3. IMG_20240329_132735640_.jpg

    IMG_20240329_132735640_.jpg

  4. IMG_20240329_121339576_HDR_.jpg

    IMG_20240329_121339576_HDR_.jpg

  5. IMG_20240329_121336151_HDR_.jpg

    IMG_20240329_121336151_HDR_.jpg

  6. IMG_20240329_121327788_.jpg

    IMG_20240329_121327788_.jpg

  7. R

    Pool heater leaking

    I do maintain the pool chemistry. Testing both pH and chlorine levels on a weekly basis. With the salt system, the pH of the pool is normally drifting to the basic side pH > 8; my pool is 20k gallons of water; normally add about 64 oz of muriatic acid, in portions around the pool; that...
  8. heat exchanger 2_.jpg

    heat exchanger 2_.jpg

  9. heatexchanger  1_.jpg

    heatexchanger 1_.jpg

  10. R

    Pool heater leaking

    Thanks; it all now makes sense since the salt chlorinator system is located after the pool heater. I have a second vendor tomorrow to provide a second opinion. Any additional recommendations... appreciate it as well other forum members!
  11. R

    Pool heater leaking

    Pool heater leaking from the bottom, drops, probably losing 1 gallon of water when circulating water with or without the heater functioning. I've added pictures of evidence of corrosion outdoors due to normal wear and tear as well as my 5 year old journal which is very detailed
  12. R

    Pool heater leaking

    Here is the narrative from the assigned vendor: You have a salt water pool and there should be a non corrosive check valve between the salt cell and the heater. One of the pictures shows you don't have one. A non corrosive stops the chemicals from back flowing into the heater when the system...
  13. R

    Pool heater leaking

    Presumably home warranty diagnosis is blaming salt system; you will notice the green tent on the heat ex-changer. That's a sure sign of chemical damage. . Warranty is denying replacement due to non-coverage attributed to secondary damage. The pool heater is Hayward pool heater is 4 years...
  14. heat exchanger 3_.jpg

    heat exchanger 3_.jpg