Recent content by petersmike

  1. P

    Hayward GLX-PCB-MAIN - Low Salt - Low Current

    Good point - to test. I found that the cell is not worn out - I actually applied 25V and 6Amp from a Bench Power Supply with Pool Water in the Cell and it worked great - Lots of Chlorine generated. I am suspecting that the current monitoring is bad - possibly the Current Sense Resistors have...
  2. P

    Hayward GLX-PCB-MAIN - Low Salt - Low Current

    I have a GLX-PCB-MAIN which is now not putting out the full 6-7 Amp needed to drive the T-15 Cell. I have verified the Cell - it works correctly. The Board will start with 25V range - reporting 3400 PPM then quickly drop to 1900 PPM while reporting 25.5V at 4 Amp. It did start with 6 Amp...