    mas985 replied to the thread Aqualink re-prime on Solar?.
    Ok, that is fine and should not be part of the problem. Not that I can see. It is odd they do not provide a mechanism to up the speed...
  • mas985
    mas985 replied to the thread Aqualink re-prime on Solar?.
    I did miss the responses, thanks. VRV location should never be lower on the return pipe. Pressure is much lower there to keep it closed...
  • mas985
    mas985 reacted to Dirk's post in the thread Aqualink re-prime on Solar? with Like Like.
    You might have missed his answers: The top of the array is ~12' above the surface of the pool the VRV is about half that height on the...
  • mas985
    mas985 replied to the thread Equipment for New Build.
    The Master Temp 400 has an internal bypass: This is much better than heaters without a bypass such as most heat pumps but not as good...
    • 1714575825618.png
  • mas985
    mas985 added the media item 1714575825618.png to New Pool Builds.
    1714575825618.png
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    One more thought. Is the clock on your P4 constantly running fast or slow? How many minutes per day/week? There have been reports of...
  • mas985
    mas985 replied to the thread Aqualink re-prime on Solar?.
    I have the Hayward AquaLogic controller. How high are the panels installed? Where is the VRV installed? What is the filter pressure...
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    You have a standard EW11 correct? Can you confirm the baud rate is correct? 19200
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    The script uses the keep alive for timing purposes and I did some timing measurements from my unit and they come in at 100 ms intervals...
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    Just curious, does the IOS app work too?
  • mas985
    mas985 reacted to elizb's post in the thread AQL-PS-8 Remote Emulator App with Like Like.
    I replaced the script with a modified one.. changed these variables. TIME _GAP = 6 KA_NEXT_TIME = SYSTIME + 60 - TIME_GAP DT= DT+60 and...
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    Did you remove the script?
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    This is the code for the filter button. See if you can send it: 100200028000800001141003 Also, with the app, see if you can try...
  • mas985
    mas985 replied to the thread AQL-PS-8 Remote Emulator App.
    It should be sending the same codes as what the local controller does. The only thing I can think of is the timing is different with...
  • mas985
    mas985 reacted to elizb's post in the thread AQL-PS-8 Remote Emulator App with Like Like.
    Troubleshooting success again! I checked the P4 mode box in settings, and am getting the display text coming over. Turning on the...