Recent content by malfield

  1. M

    Jandy Aquapure 1400 stuck on "cell reversing"

    Does anyone know whether the new controllers are still being built with reversing relays or have they gone solid state. If solid state, when did they change over. Thanks.
  2. M

    No Flow with Jandy AquaPure

    I'm confused by the term "sensor." Are you all referring to the Flow Sensor that screws into the line in front of the cell? All it is is a pair of contacts that close when the water pressure is sufficient. I've never had to repair or replace one in 12 years so I don't understand the terms...
  3. M

    Compupool cell burned

    Check your flow switch. If it failed in the closed position, power would have turned onto the cell before it filled with (cooling) water and caused it to overheat.
  4. M

    need advice on replacement for SWG - Hayward T-CELL 15

    My Chlorinator Pro T-15 is coming up on two years in Sept. So far so good. Can't see any differences between the CP T-15 and my Hayward T-15 except the price. At $299 seems to be a bargain. Very important to keep the pool chemistry optimum, especially the salt at 3200 ppm and the Stabilizer...
  5. M

    need advice on replacement for SWG - Hayward T-CELL 15

    For the past 10 months I've been running a Chlorinator Pro CP-15 plug and play replacement for the Hayward T-15. Paid $299 delivered. Seems to be operating ok. No problems. All these chlorinators have titanium plates that are coated in a precious metal combo of Ru & Ir. Chlorinator Pro claims...
  6. M

    need advice on replacement for SWG - Hayward T-CELL 15

    I've owned a pool for almost 50 years. Switched over to a Hayward System with a T-15 cell in 2002. It lasted about 9 years with tender loving care. Couldn't believe the high cost of a new Hayward cell so stuck out my neck and bought a Chlorinator Pro CP-15 for $299. Supposedl to be a generic...