    Pentari ETI 400 Heater has HLS code

    Did you figure this out?
  2. Mackboron

    Greetings - eti 400 not firing

    So I wanted to thanks those for their input and provide a bit of a conclusion. I don't know if it would help someone in the future. Apparently these eti's have more than two thermal fuses. The two in the owners manual are easily replaced and on the side. Apparently there is an additional...
  3. Mackboron

    Greetings - eti 400 not firing

    Very true! Any thoughts on that?
  4. Mackboron

    Greetings - eti 400 not firing

    Temperature differential looks to be about 25 degrees. In at 80 and out at 115 in both heaters. Stack flue temp in #2 is 125 and #4 150. After a backwash and making sure flow is optimal stack flue is 120 & 145 respectively.
  5. Mackboron

    Greetings - eti 400 not firing

    Picture of the heaters. Venting and air intake is adequate based on what I'm reading in the book. Gas was installed by a certified plumber who understood what is needed. We even had to upgrade the gas meter for the building to get the capacity we needed. Total system flow is 375 gallons per min.
  6. IMG_6936.JPG

    IMG_6936.JPG

  7. Mackboron

    Greetings - eti 400 not firing

    I totally agree that they should have included a flow meter on the installation. At that point I was pretty ignorant of the set-up and it is interesting that techs from the same company come in and ask why there isn't a flow meter. 100% Pentair should have a flow switch on these as well. I...
  8. Mackboron

    Greetings - eti 400 not firing

    Yeah, hind-sight is 20/20. The swim team bought them in order to heat the pool so we could practice. We're grass roots with a pretty tight budget. I was totally in on the process and reviewed multiple options presented to us by different pool companies. In order to install four standard pool...
  9. Mackboron

    Greetings - eti 400 not firing

    Pretty sure I haven't heard the blower turning on when the heater starts up. I'll double check tomorrow morning but I'm not kidding when I say that the orange heater light turns on for less than a second and then the service light turns on. Found this in the manual: The air flow switches...
  10. Mackboron

    Greetings - eti 400 not firing

    Thanks Joyful noise, I wasn't quite sure and appreciate you looping some folks in. Yes, I'm a little disappointed that flow gages weren't installed when the heaters were installed. I don't remember seeing a flow switch. The heaters are indoors and I did not have any issues for the last year...
  11. Mackboron

    Greetings - eti 400 not firing

    Hey all, I am a local swim coach in Portland, Or and we have been partnering with an Elks club to run practices at their pool. I have been taking care of the pool for the last 5 or 6 years and for the most part things have gone pretty well. In the summer we've heated the pool with 60 solar...