    Mastertemp bypass valve

    Thanks to TFP and the awesome contributors to this post, I diagnosed and replaced my manifold bypass this morning (and saved a ton of cash). I have a MasterTemp 400, and fortunately all of the parts were still in the manifold. Thanks everyone and Happy Thanksgiving! LB
  2. L

    Intellichlor IC40 low life, are the cells repalceable?

    Thanks Jason Looks like it's time to pony up the $500 LB
  3. L

    Intellichlor IC40 low life, are the cells repalceable?

    It's 7 years old, do I have to buy the whole unit? Is the power supply the same IC20/40? Also the pool is 10K gallons, If I have to replace I think a IC20 would be plenty, thoughts? Thanks, LB
  4. L

    Pentair Stop leak?

    Has anyone used this or anything like it? I have some leaks in my solar panels and the installer suggested this for fixing them. Pentair 48220000 1-Quarts Bottle Stop Leak Thanks, LB
  5. L

    Jandy actuator won't align correctly

    It sounds like the cam slipped out of position. pull the cover off loosen the nut, align it, (once you figure out which cam it is really easy to adjust with the power on) and tighten the nut being careful not to let the cams rotate out of position. How was it fixed the first time? LB
  6. L

    white buildup at spillway, calcium or salt? how to clean?

    We bought a home about a year ago with a 6 year old salt water pool, and have a white buildup around the spillway. What is it and best way to clean it? Thanks, LB
  7. L

    valve actuator cable length

    Thanks everyone, I actually had to pull it out of the box because it was binding with the wiring of the new panel. LB
  8. L

    valve actuator cable length

    Thinking of cleaning up my valve actuator cabling, do any installers ever shorten these cables and recrimp the plugs rather than leaving all of the extra cable rolled up? It would sure clean up the install. Thanks, LB
  9. L

    SECOND INTELLIFLO XF develops same leak?? how is this?

    Thanks MAS985, good info! LB
  10. L

    SECOND INTELLIFLO XF develops same leak?? how is this?

    Anyone have thoughts on replacing the impeller with the -8 unit for the 2hp wisperflo XF model? the diffuser is the same. LB
  11. L

    SECOND INTELLIFLO XF develops same leak?? how is this?

    Hi Tuna, Sorry, (couldn't resist :)) My XF had a chirping motor, when the Tech heard I had 2" plumbing he swore up and down the pump was 2 big, cut it out and return it. He even went so far as to Flag the install with Pentair as illegal (because I was DIY) stating I had 1.5" pipe and no drain...
  12. L

    reusing 2X2.5" valves

    Yup I follow you! need to measure my pad and see if I have enough room for the check valve and 8-10" of pipe before the pump is there a flow issue having the spa come into the side if I re orientate the valve for my config? Thanks again, LB
  13. L

    reusing 2X2.5" valves

    Thanks for the input Jason, I forgot to mention re orientating the automated valve, the Pentair's are very easy to adjust the cams (is there a flow issue having the spa come into the side?) and yes, need to get creative with the pressure side to filter, will be tight to the filter, maybe pivot...
  14. L

    reusing 2X2.5" valves

    Here is a pic, move the 3way with actuator and check valve inline with suction, move the pump back about 10" give me about 8" from pump union not to check valve. Thanks! LB